Room Sound Pressure Level from Sound Power (Direct and Reverberant)

Sound pressure level at a distance from a source in a room from sound power, directivity and room constant, the direct and reverberant parts and critical distance.

Thermal power plantProcess steam and utilitiesChemical and fertiliser

Inputs

Examples: Illustrative 95 dB source at 5 m in a hallCompressor room, hard surfacesTreated workshop

Accepted: 20 to 160
Accepted: 1 to 8
Accepted: 0.1 to 200 m
Accepted: 5 to 100,000 m²
Accepted: 1 to 99 %

Results

L_p = L_W + 10log[Q/(4πr²) + 4/R], R = Sᾱ/(1 − ᾱ). Inside the critical distance the direct field dominates and distance helps; beyond it the reverberant field dominates and only more absorption lowers the level. Q = 1 free space, 2 on a floor, 4 at a wall–floor edge, 8 in a corner.

Room constant807.69m²
Direct field level66.967
Reverberant field level66.948
Total sound pressure level69.968
Critical distance8.0171m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 95 dB source at 5 m in a hall. The inputs, in the units selected above:

InputValue
Source sound power level95.000 -
Directivity factor2.0000 -
Distance from source5.0000 m
Total room surface area900.00 m²
Mean absorption coefficient15.000 %

Applying the formula below gives:

ResultValue
Room constant158.82 m²
Direct field level73.039
Reverberant field level79.011
Total sound pressure level79.990
Critical distance2.5138 m

Open this example in the calculator and change any input.

Formula

\(L_p = L_W + 10\log_{10}\left(\frac{Q}{4\pi r^2} + \frac{4}{R}\right), \quad R = \frac{S\bar\alpha}{1 - \bar\alpha}, \quad r_c = \sqrt{\frac{QR}{16\pi}}\)

Variables

Symbol Meaning SI unit
\(L_W\) Source sound power level -
\(Q\) Directivity factor -
\(r\) Distance from source m
\(S\) Total room surface area m²
\(\bar\alpha\) Mean absorption coefficient -
\(R\) Room constant m²
\(L_d\) Direct field level -
\(L_r\) Reverberant field level -
\(L_p\) Total sound pressure level -
\(r_c\) Critical distance m

Method and standards

Room equation.

Where it is used

  • Predicting noise at operator positions.
  • Judging whether acoustic treatment will pay off.

Common mistakes

  • Using free-field formulas indoors.
  • Using α from a different frequency band.

Assumptions and limits

  • Diffuse reverberant field; single source; fairly regular room.

References

  • Diffuse-field room equation

Questions and answers

Why does moving away from a machine stop helping?

Beyond the critical distance the reverberant sound, equal everywhere in the room, dominates.

How much does adding absorption help?

Doubling the room constant lowers the reverberant level by 3 dB; near the source it makes little difference.

What do the defaults represent?

An illustrative 95 dB sound power source on the floor (Q = 2), 5 m away, in a hall of 900 m² surface with ᾱ = 0.15.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bies and Hansen, Engineering Noise Control, 4th ed. (Spon, 2009), Beranek and Vér, Noise and Vibration Control Engineering (Wiley, 1992)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.