Worked example
Example: Illustrative 95 dB source at 5 m in a hall. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Source sound power level | 95.000 - |
| Directivity factor | 2.0000 - |
| Distance from source | 5.0000 m |
| Total room surface area | 900.00 m² |
| Mean absorption coefficient | 15.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Room constant | 158.82 m² |
| Direct field level | 73.039 |
| Reverberant field level | 79.011 |
| Total sound pressure level | 79.990 |
| Critical distance | 2.5138 m |
Open this example in the calculator and change any input.
Formula
\(L_p = L_W + 10\log_{10}\left(\frac{Q}{4\pi r^2} + \frac{4}{R}\right), \quad R = \frac{S\bar\alpha}{1 - \bar\alpha}, \quad r_c = \sqrt{\frac{QR}{16\pi}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_W\) | Source sound power level | - |
| \(Q\) | Directivity factor | - |
| \(r\) | Distance from source | m |
| \(S\) | Total room surface area | m² |
| \(\bar\alpha\) | Mean absorption coefficient | - |
| \(R\) | Room constant | m² |
| \(L_d\) | Direct field level | - |
| \(L_r\) | Reverberant field level | - |
| \(L_p\) | Total sound pressure level | - |
| \(r_c\) | Critical distance | m |
Method and standards
Room equation.
Where it is used
- Predicting noise at operator positions.
- Judging whether acoustic treatment will pay off.
Common mistakes
- Using free-field formulas indoors.
- Using α from a different frequency band.
Assumptions and limits
- Diffuse reverberant field; single source; fairly regular room.
References
- Diffuse-field room equation
Questions and answers
Why does moving away from a machine stop helping?
Beyond the critical distance the reverberant sound, equal everywhere in the room, dominates.
How much does adding absorption help?
Doubling the room constant lowers the reverberant level by 3 dB; near the source it makes little difference.
What do the defaults represent?
An illustrative 95 dB sound power source on the floor (Q = 2), 5 m away, in a hall of 900 m² surface with ᾱ = 0.15.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bies and Hansen, Engineering Noise Control, 4th ed. (Spon, 2009), Beranek and Vér, Noise and Vibration Control Engineering (Wiley, 1992)