Worked example
Example: Illustrative 2 mm steel at 500 Hz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Panel material density | 7,850.0 kg/m³ |
| Panel thickness | 2.0000 mm |
| Elastic modulus | 200.00 GPa |
| Poisson's ratio | 0.30000 - |
| Frequency | 500.00 Hz |
| Speed of sound in air | 343.00 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Surface mass | 15.700 kg/m² |
| Normal-incidence mass law | 35.897 |
| Field-incidence mass law | 30.897 |
| Coincidence frequency | 6,129.3 Hz |
Open this example in the calculator and change any input.
Formula
\(TL_0 = 20\log_{10}(m''f) - 42, \quad TL_f \approx TL_0 - 5, \quad f_c = \frac{c^2}{2\pi}\sqrt{\frac{m''}{B}}, \quad B = \frac{Et^3}{12(1 - \nu^2)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Panel material density | kg/m³ |
| \(t\) | Panel thickness | m |
| \(E\) | Elastic modulus | Pa |
| \(\nu\) | Poisson's ratio | - |
| \(f\) | Frequency | 1/s |
| \(c\) | Speed of sound in air | m/s |
| \(m''\) | Surface mass | kg/m² |
| \(TL_0\) | Normal-incidence mass law | - |
| \(TL_f\) | Field-incidence mass law | - |
| \(f_c\) | Coincidence frequency | 1/s |
Method and standards
Mass law.
Where it is used
- Enclosure and partition selection.
- Checking machinery covers and lagging.
Common mistakes
- Using mass law near coincidence.
- Ignoring gaps and leaks that dominate transmission.
Assumptions and limits
- Single homogeneous panel; mass-controlled range.
References
- Mass law and coincidence of single panels
Questions and answers
Why does doubling a wall's mass add only 6 dB?
Transmission loss rises with the logarithm of mass, 20log(m), so each doubling adds 6 dB.
What is the coincidence dip?
At the frequency where bending waves in the panel travel at the trace speed of sound, the panel radiates efficiently and insulation falls.
What do the defaults represent?
An illustrative 2 mm steel panel at 500 Hz.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bies and Hansen, Engineering Noise Control, 4th ed. (Spon, 2009), Beranek and Vér, Noise and Vibration Control Engineering (Wiley, 1992)