FireCADCalc

Panel Sound Transmission Loss by the Mass Law and Coincidence

Sound transmission loss of a single panel at a frequency by the normal- and field-incidence mass law, with the panel's surface mass and coincidence frequency.

Thermal power plantProcess steam and utilitiesChemical and fertiliser

Inputs

Examples: Illustrative 2 mm steel at 500 HzGypsum board 12.5 mm at 1 kHzConcrete 150 mm at 125 Hz

Accepted: 100 to 12,000 kg/m³
Accepted: 0.1 to 500 mm
Accepted: 0.001 to 400 GPa
Accepted: 0 to 0.5
Accepted: 20 to 20,000 Hz
Accepted: 300 to 360 m/s

Results

Mass law: TL₀ = 20log(m″f) − 42 dB at normal incidence, about 5 dB less for a diffuse field; each doubling of mass or frequency adds 6 dB. Near and above the coincidence frequency f_c = (c²/2π)√(m″/B) the panel's bending waves match the sound and TL dips; damping decides how deep. Valid well above the panel's lowest resonances.

Surface mass345.00kg/m²
Normal-incidence mass law50.695
Field-incidence mass law45.695
Coincidence frequency117.31Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 mm steel at 500 Hz. The inputs, in the units selected above:

InputValue
Panel material density7,850.0 kg/m³
Panel thickness2.0000 mm
Elastic modulus200.00 GPa
Poisson's ratio0.30000 -
Frequency500.00 Hz
Speed of sound in air343.00 m/s

Applying the formula below gives:

ResultValue
Surface mass15.700 kg/m²
Normal-incidence mass law35.897
Field-incidence mass law30.897
Coincidence frequency6,129.3 Hz

Open this example in the calculator and change any input.

Formula

\(TL_0 = 20\log_{10}(m''f) - 42, \quad TL_f \approx TL_0 - 5, \quad f_c = \frac{c^2}{2\pi}\sqrt{\frac{m''}{B}}, \quad B = \frac{Et^3}{12(1 - \nu^2)}\)

Variables

Symbol Meaning SI unit
\(\rho\) Panel material density kg/m³
\(t\) Panel thickness m
\(E\) Elastic modulus Pa
\(\nu\) Poisson's ratio -
\(f\) Frequency 1/s
\(c\) Speed of sound in air m/s
\(m''\) Surface mass kg/m²
\(TL_0\) Normal-incidence mass law -
\(TL_f\) Field-incidence mass law -
\(f_c\) Coincidence frequency 1/s

Method and standards

Mass law.

Where it is used

  • Enclosure and partition selection.
  • Checking machinery covers and lagging.

Common mistakes

  • Using mass law near coincidence.
  • Ignoring gaps and leaks that dominate transmission.

Assumptions and limits

  • Single homogeneous panel; mass-controlled range.

References

  • Mass law and coincidence of single panels

Questions and answers

Why does doubling a wall's mass add only 6 dB?

Transmission loss rises with the logarithm of mass, 20log(m), so each doubling adds 6 dB.

What is the coincidence dip?

At the frequency where bending waves in the panel travel at the trace speed of sound, the panel radiates efficiently and insulation falls.

What do the defaults represent?

An illustrative 2 mm steel panel at 500 Hz.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bies and Hansen, Engineering Noise Control, 4th ed. (Spon, 2009), Beranek and Vér, Noise and Vibration Control Engineering (Wiley, 1992)

Related calculators