Expansion-Chamber Muffler Transmission Loss

Transmission loss of a simple expansion-chamber muffler from the pipe and chamber diameters and chamber length, with the peak loss and pass frequencies.

Inputs

Examples: Illustrative 50/200 mm chamber at 250 HzEngine exhaust, hot gasSmall blower silencer

Accepted: 5 to 2,000 mm
Accepted: 10 to 5,000 mm
Accepted: 10 to 10,000 mm
Accepted: 1 to 20,000 Hz
Accepted: -73.15 to 926.85 °C

Results

A sudden enlargement reflects sound back towards the source. For a chamber of area ratio m and length L the plane-wave transmission loss is TL = 10 log₁₀[1 + ¼(m − 1/m)² sin²(kL)], with k = 2πf/c. It peaks where the chamber is an odd number of quarter wavelengths long and falls to zero where it is a whole number of half wavelengths (f = nc/2L). The formula holds below the chamber's first cross mode, about 1.84c/(πd₂); real mufflers combine chambers, tubes and absorbent to fill the pass bands. Air properties are used for the speed of sound.

Area ratio10.821
Speed of sound520.11m/s
Transmission loss at the frequency (dB)11.351
Peak transmission loss (dB)14.738
First pass frequency (zero loss)520.11Hz
First frequency of peak loss260.06Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50/200 mm chamber at 250 Hz. The inputs, in the units selected above:

InputValue
Inlet and outlet pipe diameter50.000 mm
Chamber diameter200.00 mm
Chamber length300.00 mm
Frequency250.00 Hz
Gas temperature20.000 °C

Applying the formula below gives:

ResultValue
Area ratio16.000
Speed of sound343.23 m/s
Transmission loss at the frequency (dB)17.927
Peak transmission loss (dB)18.096
First pass frequency (zero loss)572.05 Hz
First frequency of peak loss286.03 Hz

Open this example in the calculator and change any input.

Formula

\(TL = 10\log_{10}\left[1 + \frac14\left(m - \frac1m\right)^2\sin^2 kL\right], \quad m = \left(\frac{d_2}{d_1}\right)^2, \quad k = \frac{2\pi f}{c}\)

Variables

Symbol Meaning SI unit
\(d_1\) Inlet and outlet pipe diameter m
\(d_2\) Chamber diameter m
\(L\) Chamber length m
\(f\) Frequency 1/s
\(T\) Gas temperature K
\(m\) Area ratio -
\(c\) Speed of sound m/s
\(TL\) Transmission loss at the frequency (dB) -
\(TL_{max}\) Peak transmission loss (dB) -
\(f_p\) First pass frequency (zero loss) 1/s
\(f_{pk}\) First frequency of peak loss 1/s

Method and standards

Expansion chamber.

Where it is used

  • Engine, blower and compressor silencers.
  • Vent and intake silencers.

Common mistakes

  • Using the formula above the first cross mode.
  • Tuning the chamber to the wrong engine firing frequency.

Assumptions and limits

  • Plane waves; no flow or absorption; rigid walls.

References

  • Plane-wave transmission loss of a simple expansion chamber

Questions and answers

How much can a simple chamber attenuate?

Up to 10 log₁₀[1 + ¼(m − 1/m)²]: about 18 dB for an area ratio of 16.

Why does it pass some frequencies?

When the chamber is a whole number of half wavelengths long it becomes acoustically transparent.

What do the defaults represent?

An illustrative 50 mm pipe into a 200 mm chamber 300 mm long, air at 20 °C, at 250 Hz.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Munjal, Acoustics of Ducts and Mufflers, 2nd ed. (Wiley, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.