Worked example
Example: Illustrative wall, window and door. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Area of element 1 (wall) | 20.000 m² |
| Transmission loss 1 | 50.000 - |
| Area of element 2 (window) | 3.0000 m² |
| Transmission loss 2 | 30.000 - |
| Area of element 3 (door or gap) | 2.0000 m² |
| Transmission loss 3 | 20.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Average transmission coefficient | 9.2800e-04 |
| Composite transmission loss | 30.325 |
| Transmission loss of element 1 alone | 50.000 |
| Share of sound through element 3 | 86.207 % |
Open this example in the calculator and change any input.
Formula
\(TL_c = -10\log_{10}\frac{\sum S_i10^{-TL_i/10}}{\sum S_i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_1\) | Area of element 1 (wall) | m² |
| \(TL_1\) | Transmission loss 1 | - |
| \(S_2\) | Area of element 2 (window) | m² |
| \(TL_2\) | Transmission loss 2 | - |
| \(S_3\) | Area of element 3 (door or gap) | m² |
| \(TL_3\) | Transmission loss 3 | - |
| \(\bar\tau\) | Average transmission coefficient | - |
| \(TL_c\) | Composite transmission loss | - |
| \(TL_{1,only}\) | Transmission loss of element 1 alone | - |
| \(\eta_3\) | Share of sound through element 3 | - |
Method and standards
Composite TL.
Where it is used
- Control rooms and enclosures in plants.
- Building facades and partitions.
Common mistakes
- Averaging TL values directly.
- Ignoring ventilation openings.
Assumptions and limits
- Elements in the same band; diffuse incidence.
References
- Area-weighted transmission coefficient
Questions and answers
Why does a small gap matter so much?
Sound energy through an opening is not reduced at all, so even 1 % open area limits TL to about 20 dB.
How do I improve a composite wall?
Upgrade the weakest element first: seals on doors, laminated or double glazing, closing gaps.
What do the defaults represent?
An illustrative 20 m² wall of TL 50 with a 3 m² window of TL 30 and a 2 m² door of TL 20.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bies and Hansen, Engineering Noise Control, 4th ed. (Spon, 2009)