FireCADCalc

Piezoelectric Accelerometer: Charge and Voltage Output

Charge from a piezoelectric accelerometer, charge amplifier output, voltage-mode output loss from cable capacitance, and the amplifier's low-frequency cut-off.

Inputs

Examples: Illustrative 10 pC/g sensor at 5 gLong 30 m cable, 100 pC/gShock sensor 0.4 pC/g at 1000 g

Accepted: 0.01 to 10,000
Accepted: 1.02E-5 to 10,197 g
Accepted: 0.1 to 1,000,000 pF
Accepted: 0.1 to 10,000,000 MΩ
Accepted: 0.1 to 1,000,000 pF
Accepted: 0 to 1,000,000 pF

Results

A piezoelectric accelerometer produces charge q = S_q·a. A charge amplifier converts it to V = q/C_f regardless of cable length, because the cable capacitance sits at virtual ground. A plain voltage amplifier sees q/(C_s + C_c), so long cables reduce the signal. The feedback resistor sets the low-frequency limit f_L = 1/(2πR_fC_f). IEPE sensors have the amplifier built in and avoid this issue.

Charge50.000pC
Charge amplifier output5.0000mV
Voltage-mode output with cable11.111mV
Voltage loss from the cable66.667%
Low-frequency cut-off0.001592Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 pC/g sensor at 5 g. The inputs, in the units selected above:

InputValue
Charge sensitivity (pC per g)10.000 -
Acceleration5.0000 g
Charge amplifier feedback capacitance1,000.0 pF
Feedback resistance1,000.0 MΩ
Accelerometer capacitance1,200.0 pF
Cable capacitance1,000.0 pF

Applying the formula below gives:

ResultValue
Charge50.000 pC
Charge amplifier output50.000 mV
Voltage-mode output with cable22.727 mV
Voltage loss from the cable45.455 %
Low-frequency cut-off0.15915 Hz

Open this example in the calculator and change any input.

Formula

\(q = S_qa, \quad V_o = \frac{q}{C_f}, \quad V_v = \frac{q}{C_s + C_c}, \quad f_L = \frac1{2\pi R_fC_f}\)

Variables

Symbol Meaning SI unit
\(S_q\) Charge sensitivity (pC per g) -
\(a\) Acceleration m/s²
\(C_f\) Charge amplifier feedback capacitance F
\(R_f\) Feedback resistance Ω
\(C_s\) Accelerometer capacitance F
\(C_c\) Cable capacitance F
\(q\) Charge C
\(V_o\) Charge amplifier output V
\(V_v\) Voltage-mode output with cable V
\(C_c/(C_s + C_c)\) Voltage loss from the cable -
\(f_L\) Low-frequency cut-off 1/s

Method and standards

Charge amplifier.

Where it is used

  • Vibration measurement chain design.
  • Troubleshooting low readings.

Common mistakes

  • Forgetting cable capacitance in voltage mode.
  • Mixing pC/g and pC/(m/s²).

Assumptions and limits

  • Ideal charge amplifier; linear sensor.

References

  • Piezoelectric transducer and charge amplifier

Questions and answers

Why use a charge amplifier?

Its output does not depend on cable capacitance, so long or changing cables do not alter the calibration.

What limits low-frequency measurement?

Charge leaks away through the feedback resistor; the time constant R_fC_f sets the lowest usable frequency.

What do the defaults represent?

An illustrative 10 pC/g accelerometer (1.2 nF) at 5 g with a 1 nF feedback capacitor, 1 GΩ feedback resistor and 1 nF of cable.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serridge and Licht, Piezoelectric Accelerometers and Vibration Preamplifiers (Brüel & Kjær, 1987), Lipták (ed.), Instrument Engineers' Handbook, Vol. 1: Process Measurement and Analysis, 4th ed. (CRC Press, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.