Worked example
Example: 50 m³/h in DN80, 22 mm body. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume flow | 50.000 m³/h |
| Pipe inside diameter | 77.900 mm |
| Bluff body width | 22.000 mm |
| Strouhal number | 0.20000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean velocity in the pipe | 2.9141 m/s |
| Shedding frequency St v / d | 26.492 Hz |
| Pulses per m³ | 1,907.4 |
Open this example in the calculator and change any input.
Formula
\(f = \frac{St\, v}{d}, \quad K = \frac{f}{Q} = \frac{St}{d\, A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Volume flow | m³/s |
| \(D\) | Pipe inside diameter | m |
| \(d\) | Bluff body width | m |
| \(St\) | Strouhal number | - |
| \(v\) | Mean velocity in the pipe | m/s |
| \(f\) | Shedding frequency St v / d | 1/s |
| \(K\) | Pulses per m³ | - |
Method and standards
Strouhal relation for periodic vortex shedding.
Where it is used
- Vortex meter range checks.
- Vibration of pipes and thermowells in flow.
Common mistakes
- Using pipe diameter for body width.
- Ignoring the low-flow limit.
Assumptions and limits
The mean pipe velocity is used. The real shedding frequency depends on the gap velocity past the body (higher than the pipe mean because of blockage), which the meter's calibrated K-factor includes.
No Reynolds-number check: shedding is regular only above a minimum Reynolds number given by the meter maker (typically a few thousand to about 20 000); below it the meter cuts off.
Constant Strouhal number.
References
- Strouhal relation f = St v / d (von Kármán vortex street)
Questions and answers
What frequency at 50 m³/h in DN80 with a 22 mm body?
Velocity 2.91 m/s; frequency 26 Hz.
Why is the K-factor constant?
St is nearly constant over a wide Reynolds range, so frequency is proportional to flow.
What limits low flow?
Below a minimum Reynolds number vortices are irregular.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.