Worked example
Example: 152.0 / 151.6 µs, 226 mm path at 45°, DN150. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Transit time upstream (against the flow) | 1.5200e-04 s |
| Transit time downstream (with the flow) | 1.5160e-04 s |
| Acoustic path length | 226.30 mm |
| Angle of the path to the pipe axis | 45.000 ° |
| Pipe inside diameter | 160.00 mm |
| Profile factor (mean / path velocity) | 0.94000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Velocity along the path axis | 2.7777 m/s |
| Speed of sound in the fluid | 1,490.8 m/s |
| Mean velocity in the pipe | 2.6110 m/s |
| Volume flow | 188.99 m³/h |
Open this example in the calculator and change any input.
Formula
\(v_L = \frac{L}{2\cos\theta}\, \frac{t_{up} - t_{dn}}{t_{up}\, t_{dn}}, \quad c = \frac{L}{2}\, \frac{t_{up} + t_{dn}}{t_{up}\, t_{dn}}, \quad Q = k_h v_L \frac{\pi D^2}{4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t_{up}\) | Transit time upstream (against the flow) | s |
| \(t_{dn}\) | Transit time downstream (with the flow) | s |
| \(L\) | Acoustic path length | m |
| \(\theta\) | Angle of the path to the pipe axis | rad |
| \(D\) | Pipe inside diameter | m |
| \(k_h\) | Profile factor (mean / path velocity) | - |
| \(v_L\) | Velocity along the path axis | m/s |
| \(c\) | Speed of sound in the fluid | m/s |
| \(v_m\) | Mean velocity in the pipe | m/s |
| \(Q\) | Volume flow | m³/s |
Method and standards
Sound travels faster with the flow than against it.
Where it is used
- Clamp-on surveys of water and condensate.
- Checking meter configuration.
Common mistakes
- Wrong path length or angle.
- Profile factor of 1 in laminar flow.
Assumptions and limits
The profile factor k_h is entered, not computed. For a diametral single path it is 0.75 in laminar flow and rises to about 0.93–0.96 in turbulent flow as the Reynolds number increases; meters compute it from Re internally.
Single path, fully developed flow.
References
- Transit-time principle v = L (t_up − t_dn)/(2 cos θ t_up t_dn)
Questions and answers
What velocity do 152.0 and 151.6 µs give on a 226 mm path at 45°?
2.78 m/s along the axis.
Why does temperature not matter?
Speed of sound cancels when the two times are combined this way.
What is the profile factor?
A single path sees the centre-weighted velocity; the factor converts it to the mean.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.