Worked example
Example: 0.6 m flume, 300 mm head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Throat width | 600.00 mm |
| Upstream head | 300.00 mm |
| Downstream head (for submergence) | 120.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Free-flow discharge | 784.01 m³/h |
| Head exponent | 1.5483 |
| Submergence ratio | 40.000 % |
Open this example in the calculator and change any input.
Formula
\(Q = 0.372W\left(\frac{H_a}{0.3048}\right)^{1.569W^{0.026}}\ \ (\mathrm{SI})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Throat width | m |
| \(H_a\) | Upstream head | m |
| \(H_b\) | Downstream head (for submergence) | m |
| \(Q\) | Free-flow discharge | m³/s |
| \(n\) | Head exponent | - |
| \(H_b/H_a\) | Submergence ratio | - |
Method and standards
USBR free-flow equation.
Where it is used
- Effluent treatment plant flow.
- Cooling water return channels.
Common mistakes
- Measuring head at the wrong point.
- Ignoring submergence.
Assumptions and limits
- Standard Parshall dimensions; free flow.
References
- Parshall flume free-flow equation Q = 0.372W(H_a/0.3048)^(1.569W^0.026) (US Bureau of Reclamation, Water Measurement Manual)
Questions and answers
Why a flume rather than a weir?
A flume passes solids and loses little head; it suits effluent and irrigation channels.
What is free flow?
When the downstream level is low enough not to back up into the throat; above about 70 % submergence the reading needs correction.
What do the defaults represent?
A 0.6 m flume with 300 mm upstream head.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.