FireCADCalc

Orifice Plate Flow (ISO 5167)

Mass and volume flow through an orifice plate from the differential pressure, by ISO 5167-2 with the Reader-Harris/Gallagher discharge coefficient and expansibility.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserISO 5167 (differential-pressure flow)

Inputs

Examples: Water 20 °C, DN100 (102.3 mm), bore 60 mm, 250 mbar, flange tapsSteam 10 bar(a) / 200 °C, DN150 (154.1 mm), bore 90 mm, 250 mbar, D and D/2 tapsNatural gas 5 bar(a), DN200 (202.7 mm), bore 100 mm, 100 mbar, corner tapsFeedwater 105 °C, DN50 (52.5 mm), bore 30 mm, 500 mbar, corner taps

Needed for gases and steam (expansibility). Absolute; choose a gauge unit to enter gauge readings.
0 for liquids. Air and flue gas 1.4; natural gas 1.31; superheated steam 1.3; saturated steam 1.135.

Results

Mass flow7,222.0kg/h
Volume flow at upstream conditions1,487.9m³/h
Discharge coefficient0.60631
Expansibility factor0.99241
Diameter ratio d/D0.58404
Pipe Reynolds number1,042,480
Permanent pressure loss161.57mbar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 20 °C, DN100 (102.3 mm), bore 60 mm, 250 mbar, flange taps. The inputs, in the units selected above:

InputValue
Pipe inside diameter102.30 mm
Orifice bore60.000 mm
Pressure tappingsFlange
Differential pressure250.00 mbar
Upstream pressure (absolute)5.0000 bar
Density at the upstream tapping998.20 kg/m³
Dynamic viscosity1.0020 cP
Isentropic exponent (0 = liquid)0 -

Applying the formula below gives:

ResultValue
Mass flow46,627 kg/h
Volume flow at upstream conditions46.711 m³/h
Discharge coefficient0.60884
Expansibility factor1.0000
Diameter ratio d/D0.58651
Pipe Reynolds number160,880
Permanent pressure loss160.61 mbar

Open this example in the calculator and change any input.

Formula

\(q_m = \frac{C}{\sqrt{1-\beta^4}}\;\varepsilon\;\frac{\pi}{4}d^2\sqrt{2\,\Delta p\,\rho_1} \qquad \beta = \frac{d}{D} \qquad Re_D = \frac{4\,q_m}{\pi\,\mu\,D} \qquad q_V = \frac{q_m}{\rho_1}\)

Reader-Harris/Gallagher equation, with \(A = (19000\beta/Re_D)^{0.8}\) and \(M_2' = 2L_2'/(1-\beta)\):

\(C = 0.5961 + 0.0261\beta^2 - 0.216\beta^8 + 0.000521\left(\frac{10^6\beta}{Re_D}\right)^{0.7} + (0.0188 + 0.0063A)\,\beta^{3.5}\left(\frac{10^6}{Re_D}\right)^{0.3}\) \(\quad + \left(0.043 + 0.080e^{-10L_1} - 0.123e^{-7L_1}\right)(1 - 0.11A)\frac{\beta^4}{1-\beta^4} - 0.031\left(M_2' - 0.8M_2'^{\,1.1}\right)\beta^{1.3}\)

plus \(0.011(0.75-\beta)(2.8 - D/25.4)\) when \(D < 71.12\) mm (\(D\) in mm). Corner taps: \(L_1 = L_2' = 0\); D and D/2: \(L_1 = 1\), \(L_2' = 0.47\); flange: \(L_1 = L_2' = 25.4/D\).

\(\varepsilon = 1 - \left(0.351 + 0.256\beta^4 + 0.93\beta^8\right)\left[1 - \left(\frac{p_1 - \Delta p}{p_1}\right)^{1/\kappa}\right] \qquad \Delta\varpi = \frac{\sqrt{1-\beta^4(1-C^2)} - C\beta^2}{\sqrt{1-\beta^4(1-C^2)} + C\beta^2}\,\Delta p\)

Variables

Symbol Meaning SI unit
\(D\) pipe inside diameter at flowing temperature m
\(d\) orifice bore at flowing temperature m
\(\text{taps}\) pressure tappings: corner, D and D/2, or flange –
\(\Delta p\) differential pressure Pa
\(p_1\) absolute pressure at the upstream tapping Pa
\(\rho_1\) density at the upstream tapping kg/m³
\(\mu\) dynamic viscosity Pa·s
\(\kappa\) isentropic exponent (0 for a liquid) –
\(q_m\) mass flow kg/s
\(q_V\) volume flow at upstream conditions m³/s
\(C\) discharge coefficient –
\(\varepsilon\) expansibility factor –
\(\beta\) diameter ratio –
\(Re_D\) Reynolds number referred to the pipe diameter –
\(\Delta\varpi\) permanent pressure loss Pa
\(L_1\), \(L_2'\) tapping distances divided by \(D\) –

Method and standards

ISO 5167-2: mass flow equation of ISO 5167-1, discharge coefficient by the Reader-Harris/Gallagher (1998) equation, expansibility factor and pressure loss of ISO 5167-2 (equations of the 2003 edition, retained in the 2022 edition). The flow is found by iterating on the Reynolds number until the discharge coefficient converges.

Where it is used

  • Sizing and checking orifice flow meters for steam, water and gas.
  • Verifying a meter's range after a process change.
  • Estimating flow from a measured differential pressure.

Common mistakes

  • Using an orifice outside the ISO 5167 limits of diameter ratio and Reynolds number.
  • Short straight lengths upstream.
  • Using design density when the fluid conditions change.

Assumptions and limits

  • Limits of use of ISO 5167-2, each flagged when exceeded: d ≥ 12.5 mm; 50 mm ≤ D ≤ 1 000 mm; 0.10 ≤ β ≤ 0.75; Re_D ≥ 5 000 (and ≥ 16 000β² for β > 0.56 with corner or D and D/2 taps; ≥ 170β²D[mm] with flange taps); p₂/p₁ ≥ 0.75.
  • Square-edged concentric plate, single-phase flow, straight lengths as ISO 5167-2 requires.
  • Diameters at flowing temperature: correct d and D for thermal expansion yourself for hot service.
  • Density and viscosity are your inputs; take steam and water values from the steam and water property calculators.

References

  • ISO 5167-1 (general principles)
  • ISO 5167-2 (orifice plates)
  • Reader-Harris/Gallagher (1998) equation

Questions and answers

How is flow through an orifice plate calculated?

q_m = C/√(1−β⁴)·ε·(π/4)d²·√(2Δp·ρ₁). For water in a 102.3 mm pipe with a 60 mm bore and 250 mbar across flange taps, C = 0.6088 and the flow is 12.95 kg/s (46.7 m³/h).

Why does the calculation iterate?

The discharge coefficient depends on the Reynolds number, which depends on the flow. The calculator repeats the calculation until the coefficient stops changing.

How much of the differential pressure is lost?

Most of it for small bores. At β = 0.59 about 64 % of the differential is not recovered: 161 mbar of the 250 mbar in the example.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.