Orifice Plate Bore Sizing for a Chosen DP

Orifice bore that gives a chosen differential pressure at the maximum flow, by ISO 5167-2 (Reader-Harris/Gallagher), with β ratio and permanent pressure loss.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserISO 5167 (differential-pressure flow)

Inputs

Examples: Water 10 kg/s in DN100 (102.3 mm) at 250 mbar, flange tapsSteam 3 kg/s, 10 bar(a) 200 °C, DN150 (154.1 mm), 250 mbar, D-D/2Feedwater 6 kg/s, DN80 (77.9 mm), 500 mbar, corner

0 for liquids. Air 1.4; natural gas 1.31; superheated steam 1.3; saturated steam 1.135.

Results

Orifice bore53.456mm
Diameter ratio d/D0.52254
Discharge coefficient0.60673
Expansibility factor1.0000
Permanent pressure loss177.45mbar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 10 kg/s in DN100 (102.3 mm) at 250 mbar, flange taps. The inputs, in the units selected above:

InputValue
Pipe inside diameter102.30 mm
Maximum mass flow36,000 kg/h
Differential pressure wanted at maximum flow250.00 mbar
Pressure tappingsFlange
Upstream pressure (absolute)5.0000 bar
Density at the upstream tapping998.20 kg/m³
Dynamic viscosity1.0020 cP
Isentropic exponent (0 = liquid)0 -

Applying the formula below gives:

ResultValue
Orifice bore53.456 mm
Diameter ratio d/D0.52254
Discharge coefficient0.60673
Expansibility factor1.0000
Permanent pressure loss177.45 mbar

Open this example in the calculator and change any input.

Formula

\(q_m = \frac{C}{\sqrt{1 - \beta^4}}\,\varepsilon\,\frac{\pi}{4}d^2\sqrt{2\,\Delta p\,\rho_1} \qquad \beta = \frac{d}{D} \text{ found by bisection}\)

\(\varepsilon = 1 - (0.351 + 0.256\beta^4 + 0.93\beta^8)\left[1 - \left(\frac{p_2}{p_1}\right)^{1/\kappa}\right], \quad \Delta\varpi = \frac{\sqrt{1 - \beta^4(1 - C^2)} - C\beta^2}{\sqrt{1 - \beta^4(1 - C^2)} + C\beta^2}\,\Delta p\)

C is the Reader-Harris/Gallagher equation of ISO 5167-2 (shown in full on the orifice flow calculator), a function of β, the Reynolds number and the tapping positions.

Variables

Symbol Meaning SI unit
\(D\) pipe inside diameter m
\(q_m\) maximum mass flow kg/s
\(\Delta p\) differential pressure at max flow Pa
\(\text{taps}\) tapping arrangement –
\(p_1\) upstream pressure Pa
\(\rho_1\) upstream density kg/m³
\(\mu\) viscosity Pa·s
\(\kappa\) isentropic exponent (0 liquid) –
\(d\) bore m
\(\beta\) diameter ratio –
\(C\) discharge coefficient –
\(\varepsilon\) expansibility –
\(\Delta\varpi\) permanent pressure loss Pa

Method and standards

ISO 5167-2 orifice equation with the Reader-Harris/Gallagher discharge coefficient and the expansibility equation, solved for β by bisection.

Where it is used

  • Feedwater, steam and fuel flow elements.
  • Replacing a damaged plate.
  • Re-ranging a DP transmitter.

Common mistakes

  • Choosing β above 0.75.
  • Using nominal pipe size.
  • Forgetting straight-length requirements.

Assumptions and limits

  • The bore is searched between β 0.05 and 0.85, wider than the ISO 5167-2 range of 0.10 to 0.75; a result outside that range is given with a warning and is outside the standard's uncertainty statement.
  • Within ISO 5167-2 limits; straight lengths as the standard requires.

References

  • ISO 5167-1
  • ISO 5167-2

Questions and answers

What bore gives 250 mbar at 10 kg/s of water in DN100?

53.5 mm (β 0.52) with flange taps; C 0.607 and about 178 mbar permanent loss.

Which differential pressure should I choose?

Commonly 250–500 mbar for liquids and steam; lower for low-pressure gases. Keep β within 0.2–0.7 for best accuracy.

What about steam?

Enter density at the upstream condition and the isentropic exponent (1.3 superheated); expansibility is included.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.