Magnetic Flowmeter Velocity, Range and Signal

Velocity in a magnetic flowmeter for a flow and meter size, the electrode signal from Faraday's law, and the flow range for a velocity band.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 120 m³/h in DN1002 m³/h in DN50 (too slow)1 500 m³/h in DN300

Results

Velocity in the meter5.8946m/s
Electrode voltage B D v5.3052mV
Flow at the lowest velocity76.341m³/h
Flow at the highest velocity2,544.7m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 120 m³/h in DN100. The inputs, in the units selected above:

InputValue
Volume flow120.00 m³/h
Meter bore100.00 mm
Magnetic flux density5.0000 mT
Lowest velocity for good accuracy0.30000 m/s
Highest velocity wanted5.0000 m/s

Applying the formula below gives:

ResultValue
Velocity in the meter4.2441 m/s
Electrode voltage B D v2.1221 mV
Flow at the lowest velocity8.4823 m³/h
Flow at the highest velocity141.37 m³/h

Open this example in the calculator and change any input.

Formula

\(v = \frac{4 Q}{\pi D^2}, \quad E = B\, D\, v\)

Variables

Symbol Meaning SI unit
\(Q\) Volume flow m³/s
\(D\) Meter bore m
\(B\) Magnetic flux density T
\(v_{min}\) Lowest velocity for good accuracy m/s
\(v_{max}\) Highest velocity wanted m/s
\(v\) Velocity in the meter m/s
\(E\) Electrode voltage B D v V
\(Q_{min}\) Flow at the lowest velocity m³/s
\(Q_{max}\) Flow at the highest velocity m³/s

Method and standards

Faraday induction in the moving conductive liquid.

Where it is used

  • Meter size selection.
  • Checking a meter running at the bottom of its range.

Common mistakes

  • Choosing the line size by default.
  • Non-conductive fluids (oils).

Assumptions and limits

  • Uniform field and velocity.

References

  • Faraday's law of induction for a conductor moving in a field: E = B D v

Questions and answers

What velocity does 120 m³/h make in a DN100 meter?

4.24 m/s, inside a 0.3–5 m/s band.

How big is the signal?

With 5 mT, 2.12 mV: why electrode cables are screened.

Why size by velocity?

Accuracy is given as % of reading above a minimum velocity.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.