Worked example
Example: Feedwater control valve 60 m³/h, 95 to 89 bar(a), 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume flow | 60.000 m³/h |
| Upstream pressure (absolute) | 95.000 bar |
| Downstream pressure (absolute) | 89.000 bar |
| Liquid density at the inlet | 955.00 kg/m³ |
| Vapour pressure at the inlet temperature | 1.2090 bar |
| Critical pressure of the liquid | 220.64 bar |
| Liquid pressure recovery factor of the valve | 0.90000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow coefficient Kv (m³/h, bar) | 23.937 |
| Flow coefficient Cv (US gpm, psi) | 27.673 |
| Pressure drop across the valve | 600.00 kPa |
| Choked-flow pressure drop | 7,603.0 kPa |
| Pressure drop used for sizing | 600.00 kPa |
| Liquid critical pressure ratio factor | 0.93927 |
| Choked (1 = yes) | 0 |
Open this example in the calculator and change any input.
Formula
IEC 60534-2-1, liquid, turbulent flow, no attached fittings (\(F_P = 1\)):
\(K_v = Q\,\sqrt{\frac{\rho_1/\rho_0}{\Delta p_s}}\ \ (Q\ \text{in m}^3/\text{h},\ \Delta p_s\ \text{in bar},\ \rho_0 = 1000\ \text{kg/m}^3) \qquad C_v = \frac{K_v}{0.865}\)
\(F_F = 0.96 - 0.28\sqrt{\frac{p_v}{p_c}} \qquad \Delta p_{ch} = F_L^2\,(p_1 - F_F\,p_v) \qquad \Delta p = p_1 - p_2 \qquad \Delta p_s = \min(\Delta p,\ \Delta p_{ch})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | volume flow | m³/s |
| \(p_1\) | upstream pressure, absolute | Pa |
| \(p_2\) | downstream pressure, absolute | Pa |
| \(\rho_1\) | liquid density at the inlet | kg/m³ |
| \(p_v\) | vapour pressure at the inlet temperature | Pa |
| \(p_c\) | critical pressure of the liquid | Pa |
| \(F_L\) | liquid pressure recovery factor | – |
| \(K_v\) | flow coefficient Kv | – |
| \(C_v\) | flow coefficient Cv | – |
| \(\Delta p\) | pressure drop across the valve | Pa |
| \(\Delta p_{ch}\) | choked-flow pressure drop | Pa |
| \(\Delta p_s\) | pressure drop used for sizing | Pa |
| \(F_F\) | liquid critical pressure ratio factor | – |
| \(\text{choked}\) | 1 when the flow is choked | – |
| \(\rho_0\) | reference density of water, 1 000 | kg/m³ |
Method and standards
IEC 60534-2-1:2011 §6 for incompressible fluids in turbulent flow, with the numerical constants N₁ of its Table 1 (Kv: 1 with m³/h and bar; Cv: 0.865). The same equations appear in ANSI/ISA-75.01.01.
Where it is used
- Sizing feedwater, spray water and cooling water control valves.
- Checking an installed valve for a new duty.
- Specifying valves for purchase.
Common mistakes
- Ignoring cavitation and flashing at high pressure drop.
- Sizing at maximum flow without checking minimum flow controllability.
- Using the line size as the valve size.
Assumptions and limits
- Turbulent flow; very viscous liquids need the Reynolds-number factor F_R.
- No reducers attached to the valve (F_P = 1); with reducers the coefficient rises.
- F_L from the valve maker for the valve type and opening.
- ρ₁ and p_v are separate entries: take both at the same inlet temperature (for water, from steam tables); they are not checked against each other.
- Choked flow means cavitation or flashing: the calculation gives the coefficient; trim selection and noise are the maker's.
References
- IEC 60534-2-1:2011 (sizing equations for fluid flow)
- ANSI/ISA-75.01.01
Questions and answers
How do I calculate the Cv of a control valve?
Kv = Q·√((ρ/1000)/Δp), with Q in m³/h and Δp in bar; Cv = Kv/0.865. A feed control valve passing 60 m³/h of 105 °C water with 6 bar drop needs Kv 23.9 (Cv 27.7).
What is choked flow?
Beyond a certain pressure drop the liquid vaporises in the valve and the flow stops increasing. IEC 60534 sets that limit at F_L²(p₁ − F_F·p_v). Hot condensate dropping from 4 to 1.2 bar(a) at 140 °C is choked, and the valve must be sized on the 0.48 bar limit.
Is the valve size the Cv?
No. Choose a valve whose rated Cv is above the one calculated, with the duty in the useful part of its travel, and check the velocities; the maker's sizing program does that.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.