Control Valve Cv for Gas and Vapour

Required Cv and Kv of a control valve for gas or vapour from mass flow, inlet pressure and density, pressure drop, specific heat ratio and the valve's x_T factor.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 5 t/h at 10 bar(a), 3 bar drop, globeChoked: steam-like gas, 8 bar drop

Results

Standard gas sizing form W = N₆F_pYC_v√(xp₁ρ₁), N₆ = 27.3 (kg/h, bar, kg/m³), no fittings (F_p = 1). Above F_γx_T the flow is choked and more pressure drop gives no more flow. Select a valve with Cv about 1.25–1.4 times this at maximum flow.

Pressure-drop ratio Δp/p₁0.30000
Choked limit of x0.70000
Expansion factor0.85714
Required Cv42.314
Required Kv36.556
Choked flow (1 = yes)0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t/h at 10 bar(a), 3 bar drop, globe. The inputs, in the units selected above:

InputValue
Mass flow5,000.0 kg/h
Inlet pressure (absolute)10.000 bar
Pressure drop3.0000 bar
Inlet density8.5000 kg/m³
Ratio of specific heats1.4000 -
Pressure-drop ratio factor (valve data)0.70000 -

Applying the formula below gives:

ResultValue
Pressure-drop ratio Δp/p₁0.30000
Choked limit of x0.70000
Expansion factor0.85714
Required Cv42.314
Required Kv36.556
Choked flow (1 = yes)0

Open this example in the calculator and change any input.

Formula

\(C_v = \frac{W}{27.3\,Y\sqrt{x\,p_1\rho_1}}, \quad K_v = \frac{W}{31.6\,Y\sqrt{x\,p_1\rho_1}}, \quad Y = 1 - \frac{x}{3F_\gamma x_T}, \quad F_\gamma = \frac{\gamma}{1.4}, \quad x \le F_\gamma x_T\)

Variables

Symbol Meaning SI unit
\(W\) Mass flow kg/s
\(p_1\) Inlet pressure (absolute) Pa
\(\Delta p\) Pressure drop Pa
\(\rho_1\) Inlet density kg/m³
\(\gamma\) Ratio of specific heats -
\(x_T\) Pressure-drop ratio factor (valve data) -
\(x\) Pressure-drop ratio Δp/p₁ -
\(F_\gamma x_T\) Choked limit of x -
\(Y\) Expansion factor -
\(C_v\) Required Cv -
\(K_v\) Required Kv -
\(\text{choked}\) Choked flow (1 = yes) -

Method and standards

Gas valve sizing.

Where it is used

  • Gas, air and vapour control valves.
  • Checking an existing valve at new conditions.

Common mistakes

  • Using outlet density.
  • Ignoring choking at high drops.

Assumptions and limits

  • No pipe reducers; turbulent flow.

References

  • Gas sizing equation W = N₆F_pYC_v√(xp₁ρ₁)
  • Y = 1 − x/(3F_γx_T) (ISA-75.01 / IEC 60534-2-1 form)

Questions and answers

Why does the expansion factor matter?

Gas density falls through the vena contracta; Y corrects the liquid-type equation for that expansion, down to 2/3 at choking.

What is x_T?

The pressure-drop ratio at which flow chokes for air in that valve style: about 0.7 for globe valves, 0.15–0.3 for high-recovery butterfly and ball valves.

What do the defaults represent?

5 t/h of air-like gas at 10 bar(a) with 3 bar drop through a globe valve.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.