Worked example
Example: 35 °C, 60 % (regression). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air temperature | 35.000 °C |
| Relative humidity | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat index | 45.050 °C |
| Simple (Steadman) estimate | 36.122 °C |
| Caution band (0 none, 1 caution, 2 extreme caution, 3 danger, 4 extreme danger) | 3.0000 |
Open this example in the calculator and change any input.
Formula
\(HI = -42.379 + 2.04901523T + 10.14333127R - 0.22475541TR - 6.83783\times10^{-3}T^2 - 5.481717\times10^{-2}R^2 + 1.22874\times10^{-3}T^2R + 8.5282\times10^{-4}TR^2 - 1.99\times10^{-6}T^2R^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Air temperature | K |
| \(RH\) | Relative humidity | - |
| \(HI\) | Heat index | K |
| \(HI_s\) | Simple (Steadman) estimate | K |
| \(\text{band}\) | Caution band (0 none, 1 caution, 2 extreme caution, 3 danger, 4 extreme danger) | - |
Method and standards
NWS regression in °F and % RH, with the simple formula first.
Where it is used
- Heat stress planning for boiler houses, turbine halls and outdoor work.
- Shift and rest scheduling.
Common mistakes
- Using °C in the formula.
- Reading it as an indoor design condition.
Assumptions and limits
- Shade, light wind.
- Simple form first: HI_s = ½[T + 61 + 1.2(T − 68) + 0.094R] (°F, %). If the average of HI_s and T is 80 °F or more the regression is used, with the NWS adjustments: subtract (13 − R)/4 · √[(17 − |T − 95|)/17] when R < 13 % and 80 ≤ T ≤ 112 °F; add (R − 85)/10 · (87 − T)/5 when R > 85 % and 80 ≤ T ≤ 87 °F.
- Below about 80 °F, and above about 120 °F, a note says the value is outside the useful or fitted range.
References
- US National Weather Service heat index: Steadman simple form and the Rothfusz regression with NWS adjustments (WPC, heat index equation)
Questions and answers
35 °C at 60 % RH?
The heat index is about 45 °C: danger.
Why does humidity make it feel hotter?
Sweat evaporates more slowly, so the body sheds less heat.
Does it apply in direct sun?
No; NWS values are for shade. Full sun can add several degrees.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.