Worked example
Example: β 1.8, η 20,000 h at 8,000 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shape parameter | 1.8000 - |
| Scale (characteristic life) | 20,000 h |
| Operating time | 8,000.0 h |
| Failure fraction for the B life | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reliability | 82.516 % |
| Failure probability | 17.484 % |
| Hazard rate (per hour) | 4.3240e-05 |
| Mean life | 17,786 h |
| B life (time by which fraction p fails) | 5,728.9 h |
Open this example in the calculator and change any input.
Formula
\(R(t) = e^{-(t/\eta)^\beta}, \quad h(t) = \frac\beta\eta\left(\frac t\eta\right)^{\beta - 1}, \quad MTTF = \eta\Gamma\left(1 + \frac1\beta\right), \quad B_p = \eta[-\ln(1 - p)]^{1/\beta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\beta\) | Shape parameter | - |
| \(\eta\) | Scale (characteristic life) | s |
| \(t\) | Operating time | s |
| \(p\) | Failure fraction for the B life | - |
| \(R(t)\) | Reliability | - |
| \(F(t)\) | Failure probability | - |
| \(h(t)\) | Hazard rate (per hour) | - |
| \(MTTF\) | Mean life | s |
| \(B_p\) | B life (time by which fraction p fails) | s |
Method and standards
Weibull distribution.
Where it is used
- Maintenance intervals for pumps, fans and bearings.
- Spares planning.
Common mistakes
- Using MTTF as the replacement interval.
- Fitting β from too few failures.
Assumptions and limits
For β < 1 the hazard rate tends to infinity at t = 0; the page leaves it out there and gives it for any t above zero.
Two-parameter Weibull.
References
- Two-parameter Weibull distribution (O'Connor, Practical Reliability Engineering, ch. 2)
Questions and answers
What does the shape parameter tell me?
Whether failures are early, random or wear-out, and so whether preventive replacement helps (only for β > 1).
What is the characteristic life?
The time by which 63.2 % of items have failed, whatever the shape.
What do the defaults represent?
A wear-out component with β = 1.8 and η = 20,000 h, assessed at 8,000 h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.