Worked example
Example: Superheated enthalpy at 12 bar, 280 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First x (for example pressure) | 10.000 - |
| Second x | 15.000 - |
| First y (for example temperature) | 250.00 - |
| Second y | 300.00 - |
| Value at (x₁, y₁) | 2,943.2 - |
| Value at (x₁, y₂) | 3,051.7 - |
| Value at (x₂, y₁) | 2,924.0 - |
| Value at (x₂, y₂) | 3,038.2 - |
| x wanted | 12.000 - |
| y wanted | 280.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Interpolated value at (x, y) | 3,002.0 |
| Value at (x, y₁), first step | 2,935.5 |
| Value at (x, y₂), first step | 3,046.3 |
Open this example in the calculator and change any input.
Formula
\(z_a = z_{11} + f_x (z_{21} - z_{11}), \quad z_b = z_{12} + f_x (z_{22} - z_{12})\)
\(z = z_a + f_y (z_b - z_a), \quad f_x = \frac{x - x_1}{x_2 - x_1}, \ f_y = \frac{y - y_1}{y_2 - y_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | First x (for example pressure) | - |
| \(x_2\) | Second x | - |
| \(y_1\) | First y (for example temperature) | - |
| \(y_2\) | Second y | - |
| \(z_{11}\) | Value at (x₁, y₁) | - |
| \(z_{12}\) | Value at (x₁, y₂) | - |
| \(z_{21}\) | Value at (x₂, y₁) | - |
| \(z_{22}\) | Value at (x₂, y₂) | - |
| \(x\) | x wanted | - |
| \(y\) | y wanted | - |
| \(z\) | Interpolated value at (x, y) | - |
| \(z_a\) | Value at (x, y₁), first step | - |
| \(z_b\) | Value at (x, y₂), first step | - |
Method and standards
Linear interpolation in one direction, then in the other.
Where it is used
- Superheated steam tables.
- Any two-input table (fan curves, correction factors).
- Examinations.
Common mistakes
- Mixing up which value belongs to which corner.
- Interpolating across saturation.
Assumptions and limits
- Bilinear within one cell.
References
- Bilinear interpolation
Questions and answers
What is the enthalpy at 12 bar and 280 °C from the 10/15 bar and 250/300 °C entries?
With 2943.2, 3051.7, 2924.0 and 3038.2 kJ/kg the result is 3002.0 kJ/kg.
Does the order matter?
No: interpolating in x first or y first gives the same bilinear value.
When is it not good enough?
Near saturation or the critical point, where properties change fast.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.