FireCADCalc

Double (Bilinear) Interpolation Calculator

Value of a quantity at (x, y) inside a table with two inputs, such as superheated steam tables by pressure and temperature, by interpolating along both directions.

Boiler attendant and boiler operator examinations

Inputs

Examples: Superheated enthalpy at 12 bar, 280 °CCentre of the cellCorner value returned

Table rows and columns

Table values

Results

Interpolated value at (x, y)9.0000
Value at (x, y₁), first step7.0000
Value at (x, y₂), first step9.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Superheated enthalpy at 12 bar, 280 °C. The inputs, in the units selected above:

InputValue
First x (for example pressure)10.000 -
Second x15.000 -
First y (for example temperature)250.00 -
Second y300.00 -
Value at (x₁, y₁)2,943.2 -
Value at (x₁, y₂)3,051.7 -
Value at (x₂, y₁)2,924.0 -
Value at (x₂, y₂)3,038.2 -
x wanted12.000 -
y wanted280.00 -

Applying the formula below gives:

ResultValue
Interpolated value at (x, y)3,002.0
Value at (x, y₁), first step2,935.5
Value at (x, y₂), first step3,046.3

Open this example in the calculator and change any input.

Formula

\(z_a = z_{11} + f_x (z_{21} - z_{11}), \quad z_b = z_{12} + f_x (z_{22} - z_{12})\)

\(z = z_a + f_y (z_b - z_a), \quad f_x = \frac{x - x_1}{x_2 - x_1}, \ f_y = \frac{y - y_1}{y_2 - y_1}\)

Variables

Symbol Meaning SI unit
\(x_1\) First x (for example pressure) -
\(x_2\) Second x -
\(y_1\) First y (for example temperature) -
\(y_2\) Second y -
\(z_{11}\) Value at (x₁, y₁) -
\(z_{12}\) Value at (x₁, y₂) -
\(z_{21}\) Value at (x₂, y₁) -
\(z_{22}\) Value at (x₂, y₂) -
\(x\) x wanted -
\(y\) y wanted -
\(z\) Interpolated value at (x, y) -
\(z_a\) Value at (x, y₁), first step -
\(z_b\) Value at (x, y₂), first step -

Method and standards

Linear interpolation in one direction, then in the other.

Where it is used

  • Superheated steam tables.
  • Any two-input table (fan curves, correction factors).
  • Examinations.

Common mistakes

  • Mixing up which value belongs to which corner.
  • Interpolating across saturation.

Assumptions and limits

  • Bilinear within one cell.

References

  • Bilinear interpolation

Questions and answers

What is the enthalpy at 12 bar and 280 °C from the 10/15 bar and 250/300 °C entries?

With 2943.2, 3051.7, 2924.0 and 3038.2 kJ/kg the result is 3002.0 kJ/kg.

Does the order matter?

No: interpolating in x first or y first gives the same bilinear value.

When is it not good enough?

Near saturation or the critical point, where properties change fast.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.