FireCADCalc

Staircase Risers, Treads and Going

Number of risers, riser height, tread (going) and the total going of a straight staircase from floor-to-floor height and a target riser, with the 2R + T check.

Inputs

Examples: 3.2 m floor3.0 m floor, 150 mm risersPlant access 4.5 m

Results

Building codes set limits on riser, going and pitch; check yours. A common comfort rule is 2R + T of about 550 to 700 mm.

Number of risers (rounded)20.000
Actual riser height150.00mm
Total going (n − 1) T5.7000m
Comfort rule 2R + T600.00mm
Pitch of the stair26.565°

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3.2 m floor. The inputs, in the units selected above:

InputValue
Floor-to-floor height3.2000 m
Target riser height165.00 mm
Tread (going) per step270.00 mm

Applying the formula below gives:

ResultValue
Number of risers (rounded)19.000
Actual riser height168.42 mm
Total going (n − 1) T4.8600 m
Comfort rule 2R + T606.84 mm
Pitch of the stair31.955 °

Open this example in the calculator and change any input.

Formula

\(n = \text{round}\left(\frac{H}{R_t}\right), \quad R = \frac{H}{n}, \quad G = (n - 1)T, \quad \tan\theta = \frac{R}{T}\)

Variables

Symbol Meaning SI unit
\(H\) Floor-to-floor height m
\(R_t\) Target riser height m
\(T\) Tread (going) per step m
\(n\) Number of risers (rounded) -
\(R\) Actual riser height m
\(G\) Total going (n − 1) T m
\(2R + T\) Comfort rule 2R + T m
\(\theta\) Pitch of the stair rad

Method and standards

Geometry.

Where it is used

  • Stair layout.
  • Checking drawings.

Common mistakes

  • Equal number of risers and treads.
  • Ignoring the landing.

Assumptions and limits

  • Straight flight.
  • The number of risers is the nearest whole number, so the actual riser can be a little above the target; the page warns then, and when 2R + T is outside 550–700 mm.

References

  • Blondel's rule 2R + T (comfort check)

Questions and answers

3.2 m floor height with about 165 mm risers?

19 risers of 168.4 mm; with 270 mm treads the going is 4.86 m.

Why n − 1 treads?

The top riser lands on the floor above.

What is 2R + T?

Blondel's comfort rule, about one stride.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.