Worked example
Example: 10 m span, 2 m rise. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Span between wall plates | 10.000 m |
| Rise to the ridge | 2.0000 m |
| Eaves overhang (horizontal) | 0.50000 m |
| Length of the building along the ridge | 20.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pitch | 21.801 ° |
| Rise per run | 40.000 % |
| Rafter length including overhang | 5.9237 m |
| Roof area (both slopes) | 236.95 m² |
Open this example in the calculator and change any input.
Formula
\(\theta = \arctan\frac{R}{S/2}, \quad L_r = \sqrt{(S/2)^2 + R^2} + \frac{o}{\cos\theta}, \quad A = 2 L_r L\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Span between wall plates | m |
| \(R\) | Rise to the ridge | m |
| \(o\) | Eaves overhang (horizontal) | m |
| \(L\) | Length of the building along the ridge | m |
| \(\theta\) | Pitch | rad |
| \(R/(S/2)\) | Rise per run | - |
| \(L_r\) | Rafter length including overhang | m |
| \(A\) | Roof area (both slopes) | m² |
Method and standards
Right triangles.
Where it is used
- Roof sheeting and truss estimates.
- Rainwater design areas.
Common mistakes
- Plan area instead of slope area.
- Forgetting overhangs.
Assumptions and limits
- Symmetric duo-pitch roof.
References
- Right-triangle roof geometry
Questions and answers
10 m span, 2 m rise, 0.5 m overhang, 20 m long?
Pitch 21.8°, rafter 5.92 m, roof area 237 m².
Does the overhang count along the slope?
Yes; it is horizontal, so divide by cos θ.
Sheeting overlaps?
Add the maker's overlap allowance to the area.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.