Worked example
Example: Illustrative 5 t shrimp pond. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Biomass in the pond | 5,000.0 kg |
| Oxygen consumption (mg per kg per hour) | 500.00 - |
| Extra demand of pond water and sediment as a share of fish demand | 50.000 % |
| Standard oxygen transfer of one aerator (kg per hour) | 2.0000 - |
| Oxygen saturation at pond temperature (mg/L) | 7.9000 - |
| Oxygen level to hold (mg/L) | 4.0000 - |
| Water temperature | 28.000 °C |
| Alpha factor for pond water | 90.000 % |
| Power of one aerator | 1.5000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oxygen demand | 3.7500 |
| Field oxygen transfer per aerator (kg per hour) | 0.93363 |
| Aerators needed | 5.0000 |
| Total aerator power | 7.5000 kW |
Open this example in the calculator and change any input.
Formula
\(AOTR = SOTR\,\alpha\frac{C_s - C}{9.09}\,1.024^{T - 20}, \quad n = \frac{B\,r(1 + f_s)}{AOTR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(B\) | Biomass in the pond | kg |
| \(r\) | Oxygen consumption (mg per kg per hour) | - |
| \(f_s\) | Extra demand of pond water and sediment as a share of fish demand | - |
| \(SOTR\) | Standard oxygen transfer of one aerator (kg per hour) | - |
| \(C_s\) | Oxygen saturation at pond temperature (mg/L) | - |
| \(C\) | Oxygen level to hold (mg/L) | - |
| \(T\) | Water temperature | K |
| \(\alpha\) | Alpha factor for pond water | - |
| \(P_a\) | Power of one aerator | W |
| \(D\) | Oxygen demand | - |
| \(AOTR\) | Field oxygen transfer per aerator (kg per hour) | - |
| \(n\) | Aerators needed | - |
| \(P\) | Total aerator power | W |
Method and standards
Aerator sizing.
Where it is used
- Fish and shrimp pond aeration.
- Night-time oxygen management.
Common mistakes
- Using the standard rating as the field rate.
- Ignoring pond water and sediment demand.
Assumptions and limits
- Steady night-time demand; uniform mixing.
References
- ASCE standard-to-field oxygen transfer correction
Questions and answers
How many 2 hp paddle wheels for 5 t of shrimp?
With 500 mg/kg/h plus 50 % pond demand, about 3.75 kg O₂/h: five 2 kg/h aerators at 28 °C holding 4 mg/L, since each transfers only about 0.93 kg/h in the pond.
Why is field transfer lower than the rating?
The pond already holds oxygen, so the driving force (C_s − C) is smaller than at zero oxygen.
What do the defaults represent?
An illustrative 5 t of shrimp at 28 °C, 500 mg/kg/h, 50 % extra pond demand, 2 kg/h SOTR, 1.5 kW aerators holding 4 mg/L.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Boyd and Tucker, Pond Aquaculture Water Quality Management (Kluwer, 1998)