Worked example
Example: Illustrative 4 m head, 3 m cut-off. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Seepage head | 4.0000 m |
| Depth of the downstream cut-off | 3.0000 m |
| Total floor length | 40.000 m |
| Safe exit gradient for the soil | 0.16667 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| b/d | 13.333 |
| λ | 7.1854 |
| Exit gradient | 0.15833 |
| Safety ratio (≥ 1 safe) | 1.0527 |
| Cut-off depth for the safe gradient | 2.7260 m |
Open this example in the calculator and change any input.
Formula
\(G_E = \frac{H}{d\pi\sqrt\lambda}, \quad \lambda = \frac{1 + \sqrt{1 + \alpha^2}}{2}, \quad \alpha = \frac bd\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Seepage head | m |
| \(d\) | Depth of the downstream cut-off | m |
| \(b\) | Total floor length | m |
| \(G_s\) | Safe exit gradient for the soil | - |
| \(\alpha\) | b/d | - |
| \(\lambda\) | λ | - |
| \(G_E\) | Exit gradient | - |
| \(G_s/G_E\) | Safety ratio (≥ 1 safe) | - |
| \(d_{req}\) | Cut-off depth for the safe gradient | m |
Method and standards
Exit gradient.
Where it is used
- Weir, barrage and regulator design.
- Civil engineering examinations.
Common mistakes
- Using the upstream cut-off depth.
- Using a safe gradient for the wrong soil.
Assumptions and limits
- Floor of negligible thickness; homogeneous soil.
References
- Classical irrigation engineering relations (duty and delta, Bligh and Lane creep, Khosla exit gradient)
Questions and answers
What is the exit gradient for 4 m head, 3 m cut-off and 40 m floor?
About 0.158 (1 in 6.3), just within 1/6 for fine sand.
How can the exit gradient be reduced?
Deepen the downstream cut-off or lengthen the floor.
What do the defaults represent?
An illustrative weir with 4 m seepage head, a 3 m downstream cut-off and a 40 m floor, safe gradient 1/6.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.