Greenhouse Heating Load

Heating load of a greenhouse from cover area, cover U-value, air leakage and the inside and outside design temperatures, per square metre of floor.

Inputs

Examples: Illustrative 1000 m2 glasshouseDouble-film polyhouseSmall nursery

Accepted: 1 to 1,000,000 m²
Accepted: 1 to 1,000,000 m²
Accepted: 0.5 to 10 W/(m²·K)
Accepted: 0 to 10 1/h
Accepted: 1 to 10,000,000 m³
Accepted: 0 to 40 °C
Accepted: -40 to 30 °C

Results

A greenhouse loses heat mostly through its cover: about 6 W/(m²·K) for single glass or film, 4 for double inflated film, lower with thermal screens. Air leakage through gaps adds N V ρ c_p ΔT; older glass houses leak 1–2 air changes per hour. Size the heater for the design night temperature with no sun; wind and a clear sky raise the losses further.

Conduction through the cover220.80kW
Air leakage30.851kW
Total heating load251.65kW
Load per floor area251.65W/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1000 m2 glasshouse. The inputs, in the units selected above:

InputValue
Floor area1,000.0 m²
Cover (glazing) area1,600.0 m²
Cover U-value6.0000 W/(m²·K)
Air changes per hour1.0000 1/h
Greenhouse volume4,000.0 m³
Inside design temperature18.000 °C
Outside design temperature-5.0000 °C

Applying the formula below gives:

ResultValue
Conduction through the cover220.80 kW
Air leakage30.851 kW
Total heating load251.65 kW
Load per floor area251.65 W/m²

Open this example in the calculator and change any input.

Formula

\(\dot Q = U A_c(T_i - T_o) + N V \rho c_p (T_i - T_o)\)

Variables

Symbol Meaning SI unit
\(A_f\) Floor area m²
\(A_c\) Cover (glazing) area m²
\(U\) Cover U-value W/(m²·K)
\(N\) Air changes per hour 1/s
\(V\) Greenhouse volume m³
\(T_i\) Inside design temperature K
\(T_o\) Outside design temperature K
\(\dot Q_c\) Conduction through the cover W
\(\dot Q_i\) Air leakage W
\(\dot Q\) Total heating load W
\(\dot Q/A_f\) Load per floor area W/m²

Method and standards

Greenhouse heating.

Where it is used

  • Greenhouse and polyhouse heating design.
  • Comparing covers and screens.

Common mistakes

  • Using floor area for the cover area.
  • Ignoring leakage.

Assumptions and limits

  • Steady night conditions; no solar gain.

References

  • Greenhouse heat balance: cover conduction and air leakage

Questions and answers

How big a heater does a 1,000 m² greenhouse need?

For 18 °C inside and −5 °C outside with single glazing, about 250 kW.

How do thermal screens help?

They cut the effective U-value at night by 30–60 %.

What do the defaults represent?

An illustrative 1,000 m² glasshouse with 1,600 m² of single glazing, 1 air change per hour, 18 °C inside and −5 °C outside.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.