Worked example
Example: Illustrative 10 ha crop at peak. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reference evapotranspiration (mm per day) | 5.5000 - |
| Crop coefficient | 1.0500 - |
| Effective rainfall (mm per day) | 0.50000 - |
| Conveyance efficiency | 90.000 % |
| Application efficiency | 70.000 % |
| Irrigated area | 10.000 ha |
| Pumping hours per day | 10.000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Crop evapotranspiration (mm per day) | 5.7750 |
| Net irrigation requirement (mm per day) | 5.2750 |
| Gross irrigation requirement (mm per day) | 8.3730 |
| Water volume per day | 837.30 m³ |
| Pump flow | 23.258 L/s |
Open this example in the calculator and change any input.
Formula
\(ET_c = K_c ET_0, \quad NIR = ET_c - P_e, \quad GIR = \frac{NIR}{\eta_c\eta_a}, \quad Q = \frac{GIR\,A}{t_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(ET_0\) | Reference evapotranspiration (mm per day) | - |
| \(K_c\) | Crop coefficient | - |
| \(P_e\) | Effective rainfall (mm per day) | - |
| \(\eta_c\) | Conveyance efficiency | - |
| \(\eta_a\) | Application efficiency | - |
| \(A\) | Irrigated area | m² |
| \(t_p\) | Pumping hours per day | s |
| \(ET_c\) | Crop evapotranspiration (mm per day) | - |
| \(NIR\) | Net irrigation requirement (mm per day) | - |
| \(GIR\) | Gross irrigation requirement (mm per day) | - |
| \(V\) | Water volume per day | m³ |
| \(Q\) | Pump flow | m³/s |
Method and standards
Irrigation requirement.
Where it is used
- Irrigation system capacity.
- Canal and pump planning.
Common mistakes
- Using annual averages for peak capacity.
- Counting all rainfall as effective.
Assumptions and limits
- Daily averages for the period.
Questions and answers
How much water does 10 ha of sugarcane need in summer?
At ET₀ 5.5 mm/day and K_c 1.05 with 63 % overall efficiency, about 840 m³ a day.
What is effective rainfall?
The part of rain stored in the root zone; heavy showers run off and light ones evaporate.
What do the defaults represent?
An illustrative 10 ha crop at peak with ET₀ 5.5 mm/day, K_c 1.05, 0.5 mm/day effective rain and 90 % conveyance and 70 % application efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Allen, Pereira, Raes and Smith, Crop Evapotranspiration, FAO Irrigation and Drainage Paper 56 (FAO, 1998), Doorenbos and Pruitt, Crop Water Requirements, FAO Irrigation and Drainage Paper 24 (FAO, 1977)