Worked example
Example: Illustrative 10000 broilers. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of birds | 10,000 - |
| Live weight per bird | 2.0000 kg |
| Minimum ventilation per kg (m³/h per kg) | 0.70000 - |
| Hot-weather ventilation per kg (m³/h per kg) | 6.0000 - |
| Capacity of one fan at working pressure | 35,000 m³/h |
| House cross-section (width × average height) | 33.600 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum ventilation | 14,000 m³/h |
| Maximum ventilation | 120,000 m³/h |
| Fans for maximum ventilation | 4.0000 |
| Tunnel air speed at maximum | 0.99206 m/s |
Open this example in the calculator and change any input.
Formula
\(\dot V = n\,w\,r, \quad n_f = \left\lceil\frac{\dot V_{max}}{\dot V_f}\right\rceil, \quad v = \frac{\dot V_{max}}{A_x}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of birds | - |
| \(w\) | Live weight per bird | kg |
| \(r_{min}\) | Minimum ventilation per kg (m³/h per kg) | - |
| \(r_{max}\) | Hot-weather ventilation per kg (m³/h per kg) | - |
| \(\dot V_f\) | Capacity of one fan at working pressure | m³/s |
| \(A_x\) | House cross-section (width × average height) | m² |
| \(\dot V_{min}\) | Minimum ventilation | m³/s |
| \(\dot V_{max}\) | Maximum ventilation | m³/s |
| \(n_f\) | Fans for maximum ventilation | - |
| \(v\) | Tunnel air speed at maximum | m/s |
Method and standards
Poultry ventilation.
Where it is used
- Broiler and layer house design.
- Fan retrofits.
Common mistakes
- Using fan capacity at zero static pressure.
- Ignoring minimum ventilation in winter.
Assumptions and limits
- Rates per kg as entered.
References
- Ventilation per kg of live weight and tunnel air speed
Questions and answers
How many fans does a 10,000-bird broiler house need?
At 2 kg and 6 m³/h per kg, 120,000 m³/h: four 35,000 m³/h fans.
What tunnel air speed is used?
About 2–3 m/s for grown broilers; less for young birds.
What do the defaults represent?
An illustrative 10,000 broilers at 2 kg, 0.7 and 6 m³/h per kg, 35,000 m³/h fans, house 12 m wide and 2.8 m average height.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.