Results

Fish and shrimp use about 300–800 mg of oxygen per kg per hour, more when warm and after feeding; the water column and sediment add more. Aerators are rated at standard conditions (clean water, 20 °C, zero oxygen, saturation 9.09 mg/L). In a pond holding C mg/L the driving force is only (C_s − C), and transfer rises 2.4 % per degree: AOTR = SOTR α (C_s − C)/9.09 × 1.024^(T−20). Night-time demand without photosynthesis sets the need.

Oxygen demand4.3200
Field oxygen transfer per aerator (kg per hour)0.91445
Aerators needed5.0000
Total aerator power5.5000kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 t shrimp pond. The inputs, in the units selected above:

InputValue
Biomass in the pond5,000.0 kg
Oxygen consumption (mg per kg per hour)500.00 -
Extra demand of pond water and sediment as a share of fish demand50.000 %
Standard oxygen transfer of one aerator (kg per hour)2.0000 -
Oxygen saturation at pond temperature (mg/L)7.9000 -
Oxygen level to hold (mg/L)4.0000 -
Water temperature28.000 °C
Alpha factor for pond water90.000 %
Power of one aerator1.5000 kW

Applying the formula below gives:

ResultValue
Oxygen demand3.7500
Field oxygen transfer per aerator (kg per hour)0.93363
Aerators needed5.0000
Total aerator power7.5000 kW

Open this example in the calculator and change any input.

Formula

\(AOTR = SOTR\,\alpha\frac{C_s - C}{9.09}\,1.024^{T - 20}, \quad n = \frac{B\,r(1 + f_s)}{AOTR}\)

Variables

Symbol Meaning SI unit
\(B\) Biomass in the pond kg
\(r\) Oxygen consumption (mg per kg per hour) -
\(f_s\) Extra demand of pond water and sediment as a share of fish demand -
\(SOTR\) Standard oxygen transfer of one aerator (kg per hour) -
\(C_s\) Oxygen saturation at pond temperature (mg/L) -
\(C\) Oxygen level to hold (mg/L) -
\(T\) Water temperature K
\(\alpha\) Alpha factor for pond water -
\(P_a\) Power of one aerator W
\(D\) Oxygen demand -
\(AOTR\) Field oxygen transfer per aerator (kg per hour) -
\(n\) Aerators needed -
\(P\) Total aerator power W

Method and standards

Aerator sizing.

Where it is used

  • Fish and shrimp pond aeration.
  • Night-time oxygen management.

Common mistakes

  • Using the standard rating as the field rate.
  • Ignoring pond water and sediment demand.

Assumptions and limits

  • Steady night-time demand; uniform mixing.

References

  • ASCE standard-to-field oxygen transfer correction

Questions and answers

How many 2 hp paddle wheels for 5 t of shrimp?

With 500 mg/kg/h plus 50 % pond demand, about 3.75 kg O₂/h: five 2 kg/h aerators at 28 °C holding 4 mg/L, since each transfers only about 0.93 kg/h in the pond.

Why is field transfer lower than the rating?

The pond already holds oxygen, so the driving force (C_s − C) is smaller than at zero oxygen.

What do the defaults represent?

An illustrative 5 t of shrimp at 28 °C, 500 mg/kg/h, 50 % extra pond demand, 2 kg/h SOTR, 1.5 kW aerators holding 4 mg/L.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Boyd and Tucker, Pond Aquaculture Water Quality Management (Kluwer, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.