FireCADCalc

Permeability: Constant-Head and Falling-Head Tests

Coefficient of permeability (hydraulic conductivity) from a constant-head test (volume, time, head) or a falling-head test (heads, time, tube and sample areas).

Inputs

Examples: Falling head on siltConstant head on sandFalling head on clay

Constant head

Falling head

Results

Constant head suits sands and gravels; falling head suits silts and clays.

Coefficient of permeability1.3863e-06m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Falling head on silt. The inputs, in the units selected above:

InputValue
TestFalling head
Sample length120.00 mm
Sample cross-section78.500 cm²
Volume collected (constant head)500.00 mL
Head difference (constant head)0.50000 m
Standpipe area (falling head)0.78500 cm²
Initial head1.0000 m
Final head0.50000 m
Time600.00 s

Applying the formula below gives:

ResultValue
Coefficient of permeability1.3863e-06 m/s

Open this example in the calculator and change any input.

Formula

\(k = \frac{Q L}{A h t} \quad \text{or} \quad k = \frac{a L}{A t}\ln\frac{h_1}{h_2}\)

Variables

Symbol Meaning SI unit
\(\text{test}\) Test -
\(L\) Sample length m
\(A\) Sample cross-section m²
\(Q\) Volume collected (constant head) m³
\(h\) Head difference (constant head) m
\(a\) Standpipe area (falling head) m²
\(h_1\) Initial head m
\(h_2\) Final head m
\(t\) Time s
\(k\) Coefficient of permeability m/s

Method and standards

Darcy's law.

Where it is used

  • Soil investigation.
  • Seepage and dewatering design.

Common mistakes

  • log₁₀ instead of ln.
  • Areas mixed up.

Assumptions and limits

  • Saturated laminar flow.

References

  • Darcy's law: constant-head k = QL/(Aht); falling-head k = (aL/At) ln(h₁/h₂) (ASTM D2434; IS 2720 Part 17)

Questions and answers

Falling head, 120 mm sample, 1 m → 0.5 m in 10 min, area ratio 1:100?

k = 1.39e-06 m/s, a silt.

Which test for clay?

Falling head, or the oedometer.

Temperature?

Correct to 20 °C with the viscosity ratio if needed.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.