FireCADCalc

Hydrometer Analysis: Particle Diameter by Stokes' Law

Equivalent particle diameter at a hydrometer reading time from effective depth, water viscosity and solids specific gravity by Stokes' law, and the percent finer.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 30 min readingEarly 1 min readingLate 24 h reading, clay

Accepted: 10 to 300 mm
Accepted: 0.16667 to 3,333.3 min
Accepted: 0.5 to 2 mPa·s
Accepted: 2.2 to 3.2
Accepted: 0 to 60
Accepted: 10 to 200

Results

Stokes: D = √[18ηv/((G_s − 1)ρ_wg)] with v = L/t, L the effective depth from the hydrometer calibration at that reading. Percent finer for a 152H-type hydrometer reading in g/L: P = [G_s/(G_s − 1)]·R_c/W_s, with R_c already corrected for temperature, meniscus and dispersant. Valid for about 0.2–50 µm.

Settling velocity0.001852mm/s
Equivalent particle diameter1.3702µm
Percent finer than D25.302%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 30 min reading. The inputs, in the units selected above:

InputValue
Effective depth140.00 mm
Time since start30.000 min
Water viscosity at test temperature1.0000 mPa·s
Specific gravity of solids2.7000 -
Corrected hydrometer reading (g/L)18.000 -
Dry soil mass in 1 L suspension (g)50.000 -

Applying the formula below gives:

ResultValue
Settling velocity0.077778 mm/s
Equivalent particle diameter9.1639 µm
Percent finer than D57.176 %

Open this example in the calculator and change any input.

Formula

\(D = \sqrt{\frac{18\eta L/t}{(G_s - 1)\rho_wg}}, \quad P = \frac{G_s}{G_s - 1}\frac{R_c}{W_s}\)

Variables

Symbol Meaning SI unit
\(L\) Effective depth m
\(t\) Time since start s
\(\eta\) Water viscosity at test temperature Pa·s
\(G_s\) Specific gravity of solids -
\(R_c\) Corrected hydrometer reading (g/L) -
\(W_s\) Dry soil mass in 1 L suspension (g) -
\(v\) Settling velocity m/s
\(D\) Equivalent particle diameter m
\(P\) Percent finer than D -

Method and standards

Hydrometer.

Where it is used

  • Fine soil grading for classification.
  • Clay content estimates.

Common mistakes

  • Using total suspension height instead of effective depth.
  • Skipping the dispersant and meniscus corrections.

Assumptions and limits

  • Spherical particles; laminar settling; dilute suspension.

References

  • Stokes' law sedimentation analysis

Questions and answers

Why does the depth change with time?

As the hydrometer sinks less in a thinner suspension, the depth to its centre of buoyancy changes; calibration gives L for each reading.

Why only below 75 µm?

Coarser particles settle too fast and turbulently for Stokes' law; they are measured by sieving.

What do the defaults represent?

An illustrative reading after 30 minutes at 140 mm effective depth, water at about 20 °C, G_s 2.70, corrected reading 18 g/L with 50 g of soil.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Das and Sobhan, Principles of Geotechnical Engineering, 8th ed. (Cengage, 2014), Holtz, Kovacs and Sheahan, An Introduction to Geotechnical Engineering, 2nd ed. (Pearson, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.