Worked example
Example: Vertical wall, level fill. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Soil friction angle | 32.000 ° |
| Wall friction angle | 20.000 ° |
| Back of wall from vertical (positive when it slopes away from the fill) | 0 ° |
| Backfill slope | 0 ° |
| Unit weight of the fill | 18.000 kN/m³ |
| Wall height | 5.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Active coefficient | 0.27554 |
| Active thrust per metre ½K_aγH² | 61.996 kN/m |
| Horizontal component | 58.257 kN/m |
| Vertical component | 21.204 kN/m |
Open this example in the calculator and change any input.
Formula
\(K_a = \frac{\cos^2(\phi - \theta)}{\cos^2\theta\cos(\delta + \theta)\left[1 + \sqrt{\frac{\sin(\phi + \delta)\sin(\phi - \beta)}{\cos(\delta + \theta)\cos(\theta - \beta)}}\right]^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\phi\) | Soil friction angle | rad |
| \(\delta\) | Wall friction angle | rad |
| \(\theta\) | Back of wall from vertical (positive when it slopes away from the fill) | rad |
| \(\beta\) | Backfill slope | rad |
| \(\gamma\) | Unit weight of the fill | N/m³ |
| \(H\) | Wall height | m |
| \(K_a\) | Active coefficient | - |
| \(P_a\) | Active thrust per metre ½K_aγH² | N/m |
| \(P_h\) | Horizontal component | N/m |
| \(P_v\) | Vertical component | N/m |
Method and standards
Coulomb wedge theory.
Where it is used
- Retaining walls, bunker walls and abutments.
- Coal and ash yard walls.
Common mistakes
- Sign of θ.
- Cohesive soils.
Assumptions and limits
- Dry cohesionless backfill, planar wedge; δ not above φ.
- Sign of θ: positive when the back of the wall slopes away from the fill going up, so the fill overhangs the wall back; this raises K_a (θ = 10°, φ = 30°, δ = β = 0 gives 0.407 against 0.333 for a vertical back). Negative θ (back leaning into the fill) lowers it.
References
- Coulomb's active earth pressure coefficient (Das, Principles of Foundation Engineering)
Questions and answers
φ 32°, δ 20°, vertical wall, level fill?
K_a about 0.28; thrust on a 5 m wall about 62 kN per metre.
How does it differ from Rankine?
Coulomb includes wall friction, which lowers K_a and tilts the thrust.
Which δ?
Commonly ⅔φ for concrete on soil; your design basis decides.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.