FireCADCalc

Concrete Volume of Footings, Columns, Beams and Slabs

Concrete volume of a set of rectangular footings, columns, beams and a slab from their sizes and numbers, with the total and the volume ordered with wastage.

Inputs

Examples: Small frame: 12 footings, 12 columns, slab 180 m²Pump house: 6 footings, slab 60 m²Slab only

Footings

Columns

Beams

Slab

Results

Beam depth below the slab avoids counting the slab twice; column height between the footing top and the beam soffit likewise. Measure beam lengths as clear spans between columns: centre-to-centre lengths count the beam–column joints twice.

Footings5.4000m³
Columns2.4300m³
Beams2.7600m³
Slab7.2000m³
Total17.790m³
Volume to order (with wastage)18.680m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Small frame: 12 footings, 12 columns, slab 180 m². The inputs, in the units selected above:

InputValue
Footing length1.8000 m
Footing width1.8000 m
Footing depth0.45000 m
Number of footings12.000 -
Column width0.30000 m
Column depth0.45000 m
Column height3.6000 m
Number of columns12.000 -
Beam width0.23000 m
Beam depth below the slab0.33000 m
Total length of beams96.000 m
Slab area180.00 m²
Slab thickness0.15000 m
Wastage allowance3.0000 %

Applying the formula below gives:

ResultValue
Footings17.496 m³
Columns5.8320 m³
Beams7.2864 m³
Slab27.000 m³
Total57.614 m³
Volume to order (with wastage)59.343 m³

Open this example in the calculator and change any input.

Formula

\(V = \sum n\, L B D + \sum n\, b d h + b_b d_b L_b + A_s t_s, \quad V_o = V(1 + k_w)\)

Variables

Symbol Meaning SI unit
\(L_f\) Footing length m
\(B_f\) Footing width m
\(D_f\) Footing depth m
\(n_f\) Number of footings -
\(b_c\) Column width m
\(d_c\) Column depth m
\(h_c\) Column height m
\(n_c\) Number of columns -
\(b_b\) Beam width m
\(d_b\) Beam depth below the slab m
\(L_b\) Total length of beams m
\(A_s\) Slab area m²
\(t_s\) Slab thickness m
\(k_w\) Wastage allowance -
\(V_f\) Footings m³
\(V_c\) Columns m³
\(V_b\) Beams m³
\(V_s\) Slab m³
\(V\) Total m³
\(V_o\) Volume to order (with wastage) m³

Method and standards

Volumes of prisms.

Where it is used

  • Estimating and ordering concrete.
  • Checking bills of quantities.

Common mistakes

  • Double counting beams and slab.
  • Forgetting pedestals and plinth beams.

Assumptions and limits

  • Rectangular members.
  • Column height from the footing top to the beam soffit; beam lengths as clear spans between columns. Centre-to-centre beam lengths count each beam–column joint (b_b × d_b × column width) twice.

References

  • Volume of rectangular members (Common site practice (quantity estimating))

Questions and answers

What do the defaults add up to?

Footings 17.50, columns 5.83, beams 7.29, slab 27.0 m³: about 57.6 m³.

Why measure beams below the slab?

The slab already includes the part of the beam within its thickness.

How much wastage?

Your site figure; 2–5 % is typical for ready-mixed concrete.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.