FireCADCalc

Aggregate Moisture Correction to Batch Water

Adjusted batch weights of fine and coarse aggregate and water when the aggregates are wet or dry, from their moisture contents and absorption.

Inputs

Examples: Wet sand, damp coarseDry coarse aggregate absorbsVery wet sand: water exceeds design

Results

The aggregates bring more water than the design needs: the mix will be too wet.

Fine aggregate to weigh (as it is)855.45kg
Coarse aggregate to weigh1,116.4kg
Water to add-51.863kg
Free water brought in by the aggregates71.863kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wet sand, damp coarse. The inputs, in the units selected above:

InputValue
Fine aggregate, SSD weight in the design700.00 kg
Coarse aggregate, SSD weight1,150.0 kg
Free water in the design180.00 kg
Moisture content of the fine aggregate (of dry mass)4.0000 %
Absorption of the fine aggregate (of dry mass)1.0000 %
Moisture content of the coarse aggregate (of dry mass)0.50000 %
Absorption of the coarse aggregate (of dry mass)0.80000 %

Applying the formula below gives:

ResultValue
Fine aggregate to weigh (as it is)720.79 kg
Coarse aggregate to weigh1,146.6 kg
Water to add162.63 kg
Free water brought in by the aggregates17.369 kg

Open this example in the calculator and change any input.

Formula

\(M_{dry} = \frac{M_{SSD}}{1 + a}, \quad M_{batch} = M_{dry}(1 + m), \quad W_b = W - \sum (M_{batch} - M_{SSD})\)

Variables

Symbol Meaning SI unit
\(F_{SSD}\) Fine aggregate, SSD weight in the design kg
\(G_{SSD}\) Coarse aggregate, SSD weight kg
\(W\) Free water in the design kg
\(m_f\) Moisture content of the fine aggregate (of dry mass) -
\(a_f\) Absorption of the fine aggregate (of dry mass) -
\(m_c\) Moisture content of the coarse aggregate (of dry mass) -
\(a_c\) Absorption of the coarse aggregate (of dry mass) -
\(F_b\) Fine aggregate to weigh (as it is) kg
\(G_b\) Coarse aggregate to weigh kg
\(W_b\) Water to add kg
\(\Delta W\) Free water brought in by the aggregates kg

Method and standards

Mass balance on aggregate water.

Where it is used

  • Daily batching on site.
  • Ready-mix plant settings.

Common mistakes

  • Ignoring absorption.
  • Moisture on wet basis instead of dry.

Assumptions and limits

  • Moisture as a share of dry mass.

References

  • Moisture correction from SSD to stock condition (ACI 211.1; IS 10262 practice)

Questions and answers

Sand at 4 % moisture, 1 % absorption?

It brings about 3 % of its mass as free water: about 21 kg for 700 kg, so add less water.

What is SSD?

Saturated surface dry: pores full, surface dry; mix designs are in SSD weights.

And dry coarse aggregate?

It absorbs water from the mix; add that back.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.