Worked example
Example: Wet sand, damp coarse. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fine aggregate, SSD weight in the design | 700.00 kg |
| Coarse aggregate, SSD weight | 1,150.0 kg |
| Free water in the design | 180.00 kg |
| Moisture content of the fine aggregate (of dry mass) | 4.0000 % |
| Absorption of the fine aggregate (of dry mass) | 1.0000 % |
| Moisture content of the coarse aggregate (of dry mass) | 0.50000 % |
| Absorption of the coarse aggregate (of dry mass) | 0.80000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fine aggregate to weigh (as it is) | 720.79 kg |
| Coarse aggregate to weigh | 1,146.6 kg |
| Water to add | 162.63 kg |
| Free water brought in by the aggregates | 17.369 kg |
Open this example in the calculator and change any input.
Formula
\(M_{dry} = \frac{M_{SSD}}{1 + a}, \quad M_{batch} = M_{dry}(1 + m), \quad W_b = W - \sum (M_{batch} - M_{SSD})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_{SSD}\) | Fine aggregate, SSD weight in the design | kg |
| \(G_{SSD}\) | Coarse aggregate, SSD weight | kg |
| \(W\) | Free water in the design | kg |
| \(m_f\) | Moisture content of the fine aggregate (of dry mass) | - |
| \(a_f\) | Absorption of the fine aggregate (of dry mass) | - |
| \(m_c\) | Moisture content of the coarse aggregate (of dry mass) | - |
| \(a_c\) | Absorption of the coarse aggregate (of dry mass) | - |
| \(F_b\) | Fine aggregate to weigh (as it is) | kg |
| \(G_b\) | Coarse aggregate to weigh | kg |
| \(W_b\) | Water to add | kg |
| \(\Delta W\) | Free water brought in by the aggregates | kg |
Method and standards
Mass balance on aggregate water.
Where it is used
- Daily batching on site.
- Ready-mix plant settings.
Common mistakes
- Ignoring absorption.
- Moisture on wet basis instead of dry.
Assumptions and limits
- Moisture as a share of dry mass.
References
- Moisture correction from SSD to stock condition (ACI 211.1; IS 10262 practice)
Questions and answers
Sand at 4 % moisture, 1 % absorption?
It brings about 3 % of its mass as free water: about 21 kg for 700 kg, so add less water.
What is SSD?
Saturated surface dry: pores full, surface dry; mix designs are in SSD weights.
And dry coarse aggregate?
It absorbs water from the mix; add that back.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.