Worked example
Example: Illustrative 50 m3 hardwood charge. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Timber volume (green) | 50.000 m³ |
| Basic density (oven-dry mass per green volume) | 550.00 kg/m³ |
| Initial moisture (dry basis) | 60.000 % |
| Final moisture (dry basis) | 12.000 % |
| Specific heat of oven-dry wood | 1.4000 kJ/(kg·K) |
| Heating of the charge from ambient to kiln temperature | 50.000 K |
| Heat to evaporate wood moisture (including sorption) | 2,600.0 kJ/kg |
| Kiln efficiency (venting and structure losses) | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oven-dry wood mass | 27.500 t |
| Water removed | 13,200 kg |
| Heat supplied | 79.397 GJ |
| Heat per m³ of timber | 441.09 kWh |
| Heat per kg of water | 6.0149 MJ/kg |
Open this example in the calculator and change any input.
Formula
\(m_w = V\rho_b(M_0 - M_1), \quad Q = \frac{m_w\lambda + V\rho_b(c_w + c_{water}M_0)\Delta T}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Timber volume (green) | m³ |
| \(\rho_b\) | Basic density (oven-dry mass per green volume) | kg/m³ |
| \(M_0\) | Initial moisture (dry basis) | - |
| \(M_1\) | Final moisture (dry basis) | - |
| \(c_w\) | Specific heat of oven-dry wood | J/(kg·K) |
| \(\Delta T\) | Heating of the charge from ambient to kiln temperature | K |
| \(\lambda\) | Heat to evaporate wood moisture (including sorption) | J/kg |
| \(\eta\) | Kiln efficiency (venting and structure losses) | - |
| \(m_d\) | Oven-dry wood mass | kg |
| \(m_w\) | Water removed | kg |
| \(Q\) | Heat supplied | J |
| \(Q/V\) | Heat per m³ of timber | J |
| \(Q/m_w\) | Heat per kg of water | J/kg |
Method and standards
Timber kiln.
Where it is used
- Sawmills and furniture plants.
- Choosing between conventional and heat pump kilns.
Common mistakes
- Using wet-basis moisture.
- Using air-dry density instead of basic density.
Assumptions and limits
- Single heat-up; lumped losses.
References
- Energy balance of timber kiln drying
Questions and answers
How much water is in a cubic metre of green timber?
For 550 kg/m³ basic density at 60 % moisture, 330 kg, of which drying to 12 % removes 264 kg.
Why use dry-basis moisture for wood?
It is the trade convention: water per unit of oven-dry wood, which can exceed 100 %.
What do the defaults represent?
An illustrative 50 m³ charge of hardwood (550 kg/m³) dried from 60 % to 12 %, heated 50 K, 50 % kiln efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)