Worked example
Example: Illustrative counter-current dryer. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dryer length | 15.000 m |
| Shell diameter | 1.8000 m |
| Slope (m per m) | 3.0000 % |
| Rotational speed | 4.0000 rpm |
| Mean particle size | 500.00 µm |
| Gas mass velocity | 1.5000 kg/(m²·s) |
| Feed rate of dry solids per unit cross-section | 1.2000 kg/(m²·s) |
| Gas flow | Counter-current (slows the solids) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Retention time from geometry alone | 18.347 min |
| Correction for the gas flow | 8.2532 min |
| Retention time | 26.600 min |
| Particle-size constant B = 5 D_p^−0.5 | 0.22361 |
Open this example in the calculator and change any input.
Formula
\(\theta = \frac{0.23\,L}{S N^{0.9} D} \pm \frac{0.6\,B L G}{F}, \quad B = 5 D_p^{-0.5}\ \ \text{(US units)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Dryer length | m |
| \(D\) | Shell diameter | m |
| \(S\) | Slope (m per m) | - |
| \(N\) | Rotational speed | rad/s |
| \(D_p\) | Mean particle size | m |
| \(G\) | Gas mass velocity | kg/(m²·s) |
| \(F\) | Feed rate of dry solids per unit cross-section | kg/(m²·s) |
| \(\text{flow}\) | Gas flow | - |
| \(\theta_0\) | Retention time from geometry alone | s |
| \(\Delta\theta_G\) | Correction for the gas flow | s |
| \(\theta\) | Retention time | s |
| \(B\) | Particle-size constant B = 5 D_p^−0.5 | - |
Method and standards
Retention time.
Where it is used
- Rotary dryer and cooler design.
- Checking whether a dryer is long enough.
Common mistakes
- Using the kiln (Saeman) equation for a flighted dryer.
- Ignoring the gas drag on fine particles.
Assumptions and limits
- Flighted dryer; correlation's units converted from SI.
References
- Friedman–Marshall retention-time correlation
Questions and answers
How do slope and speed affect retention?
Retention time is inversely proportional to slope and to speed to the power 0.9.
Why does counter-current gas lengthen it?
Gas flowing against the solids drags falling particles back up the dryer.
What do the defaults represent?
An illustrative 15 m × 1.8 m counter-current dryer at 3 % slope and 4 rpm, 500 µm solids, gas 1.5 and solids 1.2 kg/(m²·s).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)