Worked example
Example: Illustrative five points. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of data points | 5.0000 - |
| Substrate 1 | 0.50000 mmol/L |
| Rate 1 (any consistent unit) | 0.82000 - |
| Substrate 2 | 1.0000 mmol/L |
| Rate 2 | 1.3300 - |
| Substrate 3 | 2.0000 mmol/L |
| Rate 3 | 1.9800 - |
| Substrate 4 | 5.0000 mmol/L |
| Rate 4 | 2.6800 - |
| Substrate 5 | 10.000 mmol/L |
| Rate 5 | 3.0500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Maximum rate | 3.6029 |
| Michaelis constant | 1.6969 mmol/L |
| Coefficient of determination of the linear fit | 0.99984 |
Open this example in the calculator and change any input.
Formula
\(\frac{1}{v} = \frac{K_m}{V_{max}}\frac{1}{S} + \frac{1}{V_{max}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of data points | - |
| \(S_1\) | Substrate 1 | mol/m³ |
| \(v_1\) | Rate 1 (any consistent unit) | - |
| \(S_2\) | Substrate 2 | mol/m³ |
| \(v_2\) | Rate 2 | - |
| \(S_3\) | Substrate 3 | mol/m³ |
| \(v_3\) | Rate 3 | - |
| \(S_4\) | Substrate 4 | mol/m³ |
| \(v_4\) | Rate 4 | - |
| \(S_5\) | Substrate 5 | mol/m³ |
| \(v_5\) | Rate 5 | - |
| \(V_{max}\) | Maximum rate | - |
| \(K_m\) | Michaelis constant | mol/m³ |
| \(R^2\) | Coefficient of determination of the linear fit | - |
Method and standards
Double-reciprocal fit.
Where it is used
- Enzyme assay analysis.
- Teaching and checking kinetic data.
Common mistakes
- Including points with substrate depletion.
- Extrapolating far beyond the data.
Assumptions and limits
- Michaelis–Menten form; initial rates.
References
- Lineweaver–Burk linearisation
Questions and answers
Why is Lineweaver–Burk criticised?
Taking reciprocals magnifies the error of the smallest rates, which then dominate the fit.
How do I spot inhibition type?
Fit with and without inhibitor: same intercept means competitive, same x-intercept non-competitive, parallel lines uncompetitive.
What do the defaults represent?
Five illustrative points from 0.5 to 10 mmol/L substrate, close to V_max 3.5 and K_m 1.6 mmol/L.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shuler and Kargi, Bioprocess Engineering: Basic Concepts, 2nd ed. (Prentice Hall, 2002)