FireCADCalc

Lineweaver–Burk Fit of Michaelis–Menten Data

Fits Vmax and Km from three to five substrate–rate pairs by linear regression of 1/v on 1/S (Lineweaver–Burk), with the coefficient of determination.

Distillery and ethanolChemical and fertiliserFood, dairy and textile

Inputs

Examples: Illustrative five pointsThree pointsFour points, high Km

Accepted: 3 to 5
Accepted: 1E-6 to 10,000 mmol/L
Accepted: 1E-9 to 1E+9
Accepted: 1E-6 to 10,000 mmol/L
Accepted: 1E-9 to 1E+9
Accepted: 1E-6 to 10,000 mmol/L
Accepted: 1E-9 to 1E+9
Accepted: 1E-6 to 10,000 mmol/L
Accepted: 1E-9 to 1E+9
Accepted: 1E-6 to 10,000 mmol/L
Accepted: 1E-9 to 1E+9

Results

1/v = (K_m/V_max)(1/S) + 1/V_max. The double-reciprocal plot overweights low-substrate points, where errors are largest; nonlinear least squares on v(S) gives better estimates. Competitive inhibition raises the slope only; non-competitive raises the intercept.

Maximum rate4.9936
Michaelis constant9.0730mmol/L
Coefficient of determination of the linear fit0.99978

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative five points. The inputs, in the units selected above:

InputValue
Number of data points5.0000 -
Substrate 10.50000 mmol/L
Rate 1 (any consistent unit)0.82000 -
Substrate 21.0000 mmol/L
Rate 21.3300 -
Substrate 32.0000 mmol/L
Rate 31.9800 -
Substrate 45.0000 mmol/L
Rate 42.6800 -
Substrate 510.000 mmol/L
Rate 53.0500 -

Applying the formula below gives:

ResultValue
Maximum rate3.6029
Michaelis constant1.6969 mmol/L
Coefficient of determination of the linear fit0.99984

Open this example in the calculator and change any input.

Formula

\(\frac{1}{v} = \frac{K_m}{V_{max}}\frac{1}{S} + \frac{1}{V_{max}}\)

Variables

Symbol Meaning SI unit
\(n\) Number of data points -
\(S_1\) Substrate 1 mol/m³
\(v_1\) Rate 1 (any consistent unit) -
\(S_2\) Substrate 2 mol/m³
\(v_2\) Rate 2 -
\(S_3\) Substrate 3 mol/m³
\(v_3\) Rate 3 -
\(S_4\) Substrate 4 mol/m³
\(v_4\) Rate 4 -
\(S_5\) Substrate 5 mol/m³
\(v_5\) Rate 5 -
\(V_{max}\) Maximum rate -
\(K_m\) Michaelis constant mol/m³
\(R^2\) Coefficient of determination of the linear fit -

Method and standards

Double-reciprocal fit.

Where it is used

  • Enzyme assay analysis.
  • Teaching and checking kinetic data.

Common mistakes

  • Including points with substrate depletion.
  • Extrapolating far beyond the data.

Assumptions and limits

  • Michaelis–Menten form; initial rates.

References

  • Lineweaver–Burk linearisation

Questions and answers

Why is Lineweaver–Burk criticised?

Taking reciprocals magnifies the error of the smallest rates, which then dominate the fit.

How do I spot inhibition type?

Fit with and without inhibitor: same intercept means competitive, same x-intercept non-competitive, parallel lines uncompetitive.

What do the defaults represent?

Five illustrative points from 0.5 to 10 mmol/L substrate, close to V_max 3.5 and K_m 1.6 mmol/L.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shuler and Kargi, Bioprocess Engineering: Basic Concepts, 2nd ed. (Prentice Hall, 2002)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.