Worked example
Example: Illustrative competitive inhibition. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Kind of inhibition | Competitive |
| Maximum rate without inhibitor | 10.000 mmol/L |
| Michaelis constant | 2.0000 mmol/L |
| Substrate concentration | 5.0000 mmol/L |
| Inhibitor concentration | 1.0000 mmol/L |
| Inhibition constant | 0.50000 mmol/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rate without inhibitor (per unit time) | 7.1429 mmol/L |
| Rate with inhibitor (per unit time) | 4.5455 mmol/L |
| Apparent Michaelis constant | 6.0000 mmol/L |
| Apparent maximum rate | 10.000 mmol/L |
| Inhibition | 36.364 % |
Open this example in the calculator and change any input.
Formula
\(v = \frac{V_{max}^{app} S}{K_m^{app} + S}, \quad \text{competitive: } K_m^{app} = K_m\left(1 + \frac{I}{K_i}\right), \quad \text{non-competitive: } V_{max}^{app} = \frac{V_{max}}{1 + I/K_i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{type}\) | Kind of inhibition | - |
| \(V_{max}\) | Maximum rate without inhibitor | mol/m³ |
| \(K_m\) | Michaelis constant | mol/m³ |
| \(S\) | Substrate concentration | mol/m³ |
| \(I\) | Inhibitor concentration | mol/m³ |
| \(K_i\) | Inhibition constant | mol/m³ |
| \(v_0\) | Rate without inhibitor (per unit time) | mol/m³ |
| \(v\) | Rate with inhibitor (per unit time) | mol/m³ |
| \(K_m^{app}\) | Apparent Michaelis constant | mol/m³ |
| \(V_{max}^{app}\) | Apparent maximum rate | mol/m³ |
| \(1 - v/v_0\) | Inhibition | - |
Method and standards
Enzyme inhibition.
Where it is used
- Enzyme process design and product inhibition.
- Interpreting assay data.
Common mistakes
- Confusing non-competitive and uncompetitive inhibition.
- Using K_i in a different concentration unit.
Assumptions and limits
- Rapid-equilibrium Michaelis–Menten kinetics; one inhibitor.
References
- Michaelis–Menten kinetics with reversible inhibition
Questions and answers
How do I tell the kind of inhibition?
From a Lineweaver–Burk plot: competitive lines meet on the 1/v axis, non-competitive on the 1/S axis, uncompetitive lines are parallel.
Can more substrate overcome inhibition?
Only competitive inhibition.
What do the defaults represent?
An illustrative enzyme with V_max 10 mmol/(L·min), K_m 2 mmol/L, 5 mmol/L substrate and 1 mmol/L inhibitor with K_i 0.5 mmol/L.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shuler and Kargi, Bioprocess Engineering: Basic Concepts, 2nd ed. (Prentice Hall, 2002)