FireCADCalc

Tube Leak Detection from the Make-Up Balance

Unaccounted water loss from make-up less blowdown, known vents and unreturned process steam: a tube leak signal as a share of steam.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 0.7 t/h unaccountedBalanced

Results

A rising unaccounted loss with steady load is the earliest sign of a tube leak; check acoustic leak detection and furnace draught.

Unaccounted loss4.7462e-16t/h
Unaccounted loss share of steam1.1866e-15%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.7 t/h unaccounted. The inputs, in the units selected above:

InputValue
Make-up water6.0000 t/h
Blowdown1.5000 t/h
Process steam not returned3.5000 t/h
Known vents, drains and sampling0.30000 t/h
Steam generated60.000 t/h

Applying the formula below gives:

ResultValue
Unaccounted loss0.70000 t/h
Unaccounted loss share of steam1.1667 %

Open this example in the calculator and change any input.

Formula

\(\dot m_u = \dot m_{mu} - \dot m_{bd} - \dot m_p - \dot m_k, \quad s = \frac{\dot m_u}{\dot m_s}\)

Variables

Symbol Meaning SI unit
\(\dot m_{mu}\) Make-up water kg/s
\(\dot m_{bd}\) Blowdown kg/s
\(\dot m_{p}\) Process steam not returned kg/s
\(\dot m_{k}\) Known vents, drains and sampling kg/s
\(\dot m_s\) Steam generated kg/s
\(\dot m_u\) Unaccounted loss kg/s
\(\dot m_u/\dot m_s\) Unaccounted loss share of steam -

Method and standards

Water mass balance over the steam–water circuit: with a steady inventory, the make-up replaces every water loss, so what is left after the known losses is unaccounted (a leak or a meter error).

Where it is used

  • Daily operation monitoring.
  • Leak investigations.

Common mistakes

  • Counting returned condensate as loss.

Assumptions and limits

  • Steady inventory.
  • All known losses must be in the inputs: put deaerator vent, soot-blowing and atomising steam, flash and trap losses on the return in the known vents.
  • No significance threshold is applied: meter errors are often several per cent of the make-up, so trend the value at steady load rather than judge one reading.

References

  • Water mass balance over the steam–water circuit

Questions and answers

Why trend it?

A single value has measurement error; a steady rise at constant load points to a leak.

Other signs?

Rising ID fan load, falling furnace draught, wet ash, a hissing noise.

Accuracy?

Make-up and blowdown meters are often the weak point: calibrate them.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.