Worked example
Example: 0.7 t/h unaccounted. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Make-up water | 6.0000 t/h |
| Blowdown | 1.5000 t/h |
| Process steam not returned | 3.5000 t/h |
| Known vents, drains and sampling | 0.30000 t/h |
| Steam generated | 60.000 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Unaccounted loss | 0.70000 t/h |
| Unaccounted loss share of steam | 1.1667 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_u = \dot m_{mu} - \dot m_{bd} - \dot m_p - \dot m_k, \quad s = \frac{\dot m_u}{\dot m_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{mu}\) | Make-up water | kg/s |
| \(\dot m_{bd}\) | Blowdown | kg/s |
| \(\dot m_{p}\) | Process steam not returned | kg/s |
| \(\dot m_{k}\) | Known vents, drains and sampling | kg/s |
| \(\dot m_s\) | Steam generated | kg/s |
| \(\dot m_u\) | Unaccounted loss | kg/s |
| \(\dot m_u/\dot m_s\) | Unaccounted loss share of steam | - |
Method and standards
Water mass balance over the steam–water circuit: with a steady inventory, the make-up replaces every water loss, so what is left after the known losses is unaccounted (a leak or a meter error).
Where it is used
- Daily operation monitoring.
- Leak investigations.
Common mistakes
- Counting returned condensate as loss.
Assumptions and limits
- Steady inventory.
- All known losses must be in the inputs: put deaerator vent, soot-blowing and atomising steam, flash and trap losses on the return in the known vents.
- No significance threshold is applied: meter errors are often several per cent of the make-up, so trend the value at steady load rather than judge one reading.
References
- Water mass balance over the steam–water circuit
Questions and answers
Why trend it?
A single value has measurement error; a steady rise at constant load points to a leak.
Other signs?
Rising ID fan load, falling furnace draught, wet ash, a hissing noise.
Accuracy?
Make-up and blowdown meters are often the weak point: calibrate them.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.