FireCADCalc

Steam, Feedwater and Fuel Flow Reconciliation

Cross-check of steam flow against feedwater minus blowdown and against fuel heat times efficiency (IF97 enthalpies), showing which meter disagrees and by how much.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Bagasse boilerCoal boiler

Results

If the steam meter disagrees with both balances in the same direction, suspect the steam meter (density compensation, DP span).

Steam from feedwater − blowdown19.900t/h
Steam from fuel heat × efficiency22.519t/h
Steam meter vs water balance0.50251%
Steam meter vs fuel balance-11.184%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bagasse boiler. The inputs, in the units selected above:

InputValue
Steam flow (meter)60.000 t/h
Feedwater flow (meter)62.500 t/h
Blowdown1.5000 t/h
Fuel flow27.000 t/h
Fuel GCV9,600.0 kJ/kg
Boiler efficiency (GCV)70.000 %
Steam pressure (absolute)46.000 bar
Steam temperature440.00 °C
Feedwater temperature105.00 °C

Applying the formula below gives:

ResultValue
Steam from feedwater − blowdown61.000 t/h
Steam from fuel heat × efficiency63.178 t/h
Steam meter vs water balance-1.6393 %
Steam meter vs fuel balance-5.0301 %

Open this example in the calculator and change any input.

Formula

\(\dot m_{s,1} = \dot m_{fw} - \dot m_{bd}, \quad \dot m_{s,2} = \frac{\dot m_{fuel}GCV\,\eta - \dot m_{bd}(h_f - h_{fw})}{h_s - h_{fw}}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Steam flow (meter) kg/s
\(\dot m_{fw}\) Feedwater flow (meter) kg/s
\(\dot m_{bd}\) Blowdown kg/s
\(\dot m_{fuel}\) Fuel flow kg/s
\(GCV\) Fuel GCV J/kg
\(\eta\) Boiler efficiency (GCV) -
\(p\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature K
\(T_{fw}\) Feedwater temperature K
\(\dot m_{s,1}\) Steam from feedwater − blowdown kg/s
\(\dot m_{s,2}\) Steam from fuel heat × efficiency kg/s
\(\epsilon_1\) Steam meter vs water balance -
\(\epsilon_2\) Steam meter vs fuel balance -

Method and standards

Mass balance (steam = feedwater − blowdown) and energy balance (fuel heat × efficiency, less the heat to the blowdown as saturated water, over the heat per kg of steam), with IAPWS-IF97 enthalpies.

Where it is used

  • Meter health checks.
  • Efficiency test preparation.

Common mistakes

  • Uncompensated steam meter.

Assumptions and limits

  • Steady load.
  • Attemperator spray taken from the feedwater after its meter, vents, drains and soot-blowing steam taken before the steam meter are not in the balance; allow for them when comparing.
  • Feedwater liquid at the steam pressure; feedwater flow above the blowdown; fuel flow above zero.

References

  • Mass balance and energy balance with IAPWS-IF97 enthalpies

Questions and answers

Why two balances?

The water balance checks the flow meters; the heat balance checks them against fuel and efficiency.

Typical disagreement?

A few per cent is normal; larger and steady errors point to a meter.

Efficiency unknown?

Use the indirect (loss) method value; then the heat balance checks the direct efficiency.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.