FireCADCalc

Specific Fuel Consumption per Tonne of Steam

Fuel per tonne of steam and evaporation ratio from daily or monthly fuel and steam totals, with the boiler efficiency they imply (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: Day: 33 t coal, 200 t steam, 18.6 MJ/kg, 10.5 bar(a) sat, feed 105 °COil: 14 t, 200 t steam, 42.5 MJ/kg, 17.5 bar(a) sat, 105 °CBagasse: 1100 t, 2400 t steam, 9.7 MJ/kg, 45 bar(a) / 400 °C, 140 °C

Results

Fuel per tonne of steam458.33kg/t
Evaporation ratio (steam per kg fuel)2.1818kg/kg
Implied boiler efficiency (on GCV, blowdown not counted)58.789%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Day: 33 t coal, 200 t steam, 18.6 MJ/kg, 10.5 bar(a) sat, feed 105 °C. The inputs, in the units selected above:

InputValue
Fuel burned in the period33.000 t
Steam generated in the period200.00 t
Gross calorific value of the fuel, as fired18,600 kJ/kg
Steam pressure (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Feedwater temperature105.00 °C

Applying the formula below gives:

ResultValue
Fuel per tonne of steam165.00 kg/t
Evaporation ratio (steam per kg fuel)6.0606 kg/kg
Implied boiler efficiency (on GCV, blowdown not counted)76.183 %

Open this example in the calculator and change any input.

Formula

\(SFC = \frac{m_f}{m_s} \qquad ER = \frac{m_s}{m_f} \qquad \eta = \frac{m_s\,(h_s - h_{fw})}{m_f \cdot GCV}\)

Variables

Symbol Meaning SI unit
\(m_f\) fuel burned in the period kg
\(m_s\) steam generated in the period kg
\(GCV\) gross calorific value as fired J/kg
\(p\) steam pressure, absolute Pa
\(\text{state}\) saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(T_{fw}\) feedwater temperature K
\(SFC\) fuel per unit of steam kg/kg
\(ER\) evaporation ratio kg/kg
\(\eta\) implied efficiency on GCV –
\(h_s\), \(h_{fw}\) steam and feedwater enthalpy (IF97) J/kg

Method and standards

Input–output totals over a period; steam and feedwater enthalpies from FireCAD's IAPWS-IF97.

Where it is used

  • Daily boiler house reports and fuel reconciliation.
  • Spotting fuel quality or meter problems early.
  • Monthly cost of steam.

Common mistakes

  • Weighing fuel as received but using an air-dried calorific value.
  • Ignoring stock changes in the bunker over the period.
  • Using a steam meter with no pressure correction.

Assumptions and limits

  • Totals over the same period; blowdown not counted in the steam, so the implied efficiency is slightly below a direct-method figure that counts it.
  • Warnings appear for an implied efficiency above 95 % or below 50 %.

References

  • IAPWS R7-97(2012) IF97
  • input–output definitions

Questions and answers

How much coal per tonne of steam is normal?

It depends on the coal and the steam. 33 t of 18.6 MJ/kg coal making 200 t of saturated steam at 10.5 bar(a) from 105 °C feedwater is 165 kg per tonne, an evaporation ratio of 6.06 and an implied efficiency of 76.2 %.

Why compare by efficiency and not just by kg per tonne?

Kg per tonne changes with the coal's calorific value and the steam conditions. The implied efficiency removes both, so a month of wet coal does not look like a bad boiler.

Is this the same as the direct-method efficiency?

Nearly: it is the input–output efficiency from period totals instead of instantaneous flows, but without the heat in the blowdown, so it reads slightly lower than a direct-method test that counts blowdown. Use the direct-method calculator for a test at steady load.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.