Heat Rate Deviation from Controllable Losses and Its Cost

Heat rate deviation and annual fuel cost from main steam, reheat, condenser pressure, exit gas and excess O₂ deviations, with user sensitivity factors.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: 100 MW unit, five deviationsGood operation, small deviations

Results

Sensitivity factors are unit-specific: take them from the turbine and boiler makers' correction curves. Default factors are typical orders of magnitude for a 100–500 MW reheat unit, not design data. Effects are added linearly.

Total heat rate deviation0.92500%
Actual heat rate8,356.6kJ/kWh
Extra fuel heat per year (GJ)153,180
Annual cost of the deviation3.8295e+07

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 MW unit, five deviations. The inputs, in the units selected above:

InputValue
Design heat rate8,640.0 kJ/kWh
Average generation100.00 MW
Hours per year7,500.0 h
Fuel cost (currency per GJ)300.00 -
Main steam temperature below design10.000 K
Heat rate change per K of main steam (%/K)0.030000 -
Reheat temperature below design8.0000 K
Heat rate change per K of reheat (%/K)0.025000 -
Condenser pressure above design (kPa)1.5000 -
Heat rate change per kPa of back pressure (%/kPa)0.90000 -
Exit gas temperature above design12.000 K
Heat rate change per K of exit gas (%/K)0.050000 -
Excess O₂ above design (percentage points)1.0000 -
Heat rate change per % O₂ (%)0.30000 -

Applying the formula below gives:

ResultValue
Total heat rate deviation2.7500 %
Actual heat rate8,877.6 kJ/kWh
Extra fuel heat per year (GJ)178,200
Annual cost of the deviation5.3460e+07

Open this example in the calculator and change any input.

Formula

\(\frac{\Delta HR}{HR} = \sum_i k_i\Delta x_i, \quad \Delta E = \frac{\Delta HR}{HR}\,HR\,Pt_a, \quad C = \Delta E\,c_f\)

Variables

Symbol Meaning SI unit
\(HR\) Design heat rate J/J
\(P\) Average generation W
\(t_a\) Hours per year s
\(c_f\) Fuel cost (currency per GJ) -
\(\Delta T_{ms}\) Main steam temperature below design K
\(k_1\) Heat rate change per K of main steam (%/K) -
\(\Delta T_{rh}\) Reheat temperature below design K
\(k_2\) Heat rate change per K of reheat (%/K) -
\(\Delta p_c\) Condenser pressure above design (kPa) -
\(k_3\) Heat rate change per kPa of back pressure (%/kPa) -
\(\Delta T_{eg}\) Exit gas temperature above design K
\(k_4\) Heat rate change per K of exit gas (%/K) -
\(\Delta O_2\) Excess O₂ above design (percentage points) -
\(k_5\) Heat rate change per % O₂ (%) -
\(\Delta HR\) Total heat rate deviation -
\(HR_a\) Actual heat rate J/J
\(\Delta E\) Extra fuel heat per year (GJ) -
\(C\) Annual cost of the deviation -

Method and standards

Linear correction factors: each deviation times its sensitivity factor, added. The default factors are typical orders of magnitude for a 100–500 MW reheat unit, not design data; use the makers' correction curves. The heat rate and fuel cost must share a basis (gross or net).

Where it is used

  • Daily performance monitoring.
  • Prioritising maintenance by cost.

Common mistakes

  • Using another unit's factors.
  • Double-counting linked effects (exit gas and excess air).

Assumptions and limits

  • Small deviations; additive effects. Exit gas temperature and excess O₂ are coupled (more air raises the exit gas temperature), so adding both can double-count; take their factors from one consistent boiler calculation.
  • The condenser pressure deviation is entered in kPa in every unit system.

References

  • Linear superposition of heat rate correction factors (performance monitoring practice; Babcock & Wilcox, Steam: Its Generation and Use, 41st ed. (2005), ch. 1)

Questions and answers

What are controllable losses?

Deviations operators can act on: steam temperatures, condenser vacuum, exit gas temperature, excess air, make-up and auxiliary power.

Why does condenser pressure dominate?

Each kPa of back pressure costs roughly 0.7–1 % of heat rate on a condensing unit.

What do the defaults give?

On a 100 MW unit at 2.4 heat rate, the five deviations add about 2.75 % to heat rate, roughly 178,000 GJ a year, about 5.3 crore at 300 per GJ.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.