Worked example
Example: 100 MW unit, five deviations. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design heat rate | 8,640.0 kJ/kWh |
| Average generation | 100.00 MW |
| Hours per year | 7,500.0 h |
| Fuel cost (currency per GJ) | 300.00 - |
| Main steam temperature below design | 10.000 K |
| Heat rate change per K of main steam (%/K) | 0.030000 - |
| Reheat temperature below design | 8.0000 K |
| Heat rate change per K of reheat (%/K) | 0.025000 - |
| Condenser pressure above design (kPa) | 1.5000 - |
| Heat rate change per kPa of back pressure (%/kPa) | 0.90000 - |
| Exit gas temperature above design | 12.000 K |
| Heat rate change per K of exit gas (%/K) | 0.050000 - |
| Excess O₂ above design (percentage points) | 1.0000 - |
| Heat rate change per % O₂ (%) | 0.30000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total heat rate deviation | 2.7500 % |
| Actual heat rate | 8,877.6 kJ/kWh |
| Extra fuel heat per year (GJ) | 178,200 |
| Annual cost of the deviation | 5.3460e+07 |
Open this example in the calculator and change any input.
Formula
\(\frac{\Delta HR}{HR} = \sum_i k_i\Delta x_i, \quad \Delta E = \frac{\Delta HR}{HR}\,HR\,Pt_a, \quad C = \Delta E\,c_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(HR\) | Design heat rate | J/J |
| \(P\) | Average generation | W |
| \(t_a\) | Hours per year | s |
| \(c_f\) | Fuel cost (currency per GJ) | - |
| \(\Delta T_{ms}\) | Main steam temperature below design | K |
| \(k_1\) | Heat rate change per K of main steam (%/K) | - |
| \(\Delta T_{rh}\) | Reheat temperature below design | K |
| \(k_2\) | Heat rate change per K of reheat (%/K) | - |
| \(\Delta p_c\) | Condenser pressure above design (kPa) | - |
| \(k_3\) | Heat rate change per kPa of back pressure (%/kPa) | - |
| \(\Delta T_{eg}\) | Exit gas temperature above design | K |
| \(k_4\) | Heat rate change per K of exit gas (%/K) | - |
| \(\Delta O_2\) | Excess O₂ above design (percentage points) | - |
| \(k_5\) | Heat rate change per % O₂ (%) | - |
| \(\Delta HR\) | Total heat rate deviation | - |
| \(HR_a\) | Actual heat rate | J/J |
| \(\Delta E\) | Extra fuel heat per year (GJ) | - |
| \(C\) | Annual cost of the deviation | - |
Method and standards
Linear correction factors: each deviation times its sensitivity factor, added. The default factors are typical orders of magnitude for a 100–500 MW reheat unit, not design data; use the makers' correction curves. The heat rate and fuel cost must share a basis (gross or net).
Where it is used
- Daily performance monitoring.
- Prioritising maintenance by cost.
Common mistakes
- Using another unit's factors.
- Double-counting linked effects (exit gas and excess air).
Assumptions and limits
- Small deviations; additive effects. Exit gas temperature and excess O₂ are coupled (more air raises the exit gas temperature), so adding both can double-count; take their factors from one consistent boiler calculation.
- The condenser pressure deviation is entered in kPa in every unit system.
References
- Linear superposition of heat rate correction factors (performance monitoring practice; Babcock & Wilcox, Steam: Its Generation and Use, 41st ed. (2005), ch. 1)
Questions and answers
What are controllable losses?
Deviations operators can act on: steam temperatures, condenser vacuum, exit gas temperature, excess air, make-up and auxiliary power.
Why does condenser pressure dominate?
Each kPa of back pressure costs roughly 0.7–1 % of heat rate on a condensing unit.
What do the defaults give?
On a 100 MW unit at 2.4 heat rate, the five deviations add about 2.75 % to heat rate, roughly 178,000 GJ a year, about 5.3 crore at 300 per GJ.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.