Worked example
Example: 22 / 18 MW export. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Export power, season | 22.000 MW |
| Season operating hours | 3,300.0 h |
| Export power, off-season | 18.000 MW |
| Off-season operating hours | 1,500.0 h |
| Tariff per kWh | 5.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy exported per year | 99,600 MWh |
| Revenue per year | 5.4780e+08 |
Open this example in the calculator and change any input.
Formula
\(E = P_s t_s + P_o t_o, \quad R = E\,c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_s\) | Export power, season | W |
| \(t_s\) | Season operating hours | s |
| \(P_o\) | Export power, off-season | W |
| \(t_o\) | Off-season operating hours | s |
| \(c\) | Tariff per kWh | - |
| \(E\) | Energy exported per year | J |
| \(R\) | Revenue per year | - |
Method and standards
Definitions.
Where it is used
- Cogeneration business cases.
Common mistakes
- MW and hours mixed with kWh tariffs.
Assumptions and limits
- Average export. Season plus off-season hours must not exceed a year (8784 h).
References
- Energy = power × hours; revenue = energy × tariff
Questions and answers
Why split the year?
Season export uses spare steam; off-season export runs on stored bagasse or bought fuel.
Currency?
Any, per kWh.
Fuel cost?
Off-season export has a fuel cost; subtract it in a full study.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.