Worked example
Example: 100 t/h bagasse boiler. The inputs, in the units selected above:
| Input | Value |
|---|---|
| FD fan | 250.00 kW |
| ID fan | 450.00 kW |
| Secondary / PA fans | 120.00 kW |
| Boiler feed pumps | 400.00 kW |
| Others (feeders, ash, ESP, water treatment) | 180.00 kW |
| Steam generated | 100.00 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total auxiliary power | 1,400.0 kW |
| Auxiliary power per tonne of steam | 14.000 kWh/t |
Open this example in the calculator and change any input.
Formula
\(P = \Sigma P_i, \quad e = \frac{P}{\dot m_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{FD}\) | FD fan | W |
| \(P_{ID}\) | ID fan | W |
| \(P_{SA}\) | Secondary / PA fans | W |
| \(P_{BFP}\) | Boiler feed pumps | W |
| \(P_o\) | Others (feeders, ash, ESP, water treatment) | W |
| \(\dot m_s\) | Steam generated | kg/s |
| \(P\) | Total auxiliary power | W |
| \(e\) | Auxiliary power per tonne of steam | J/kg |
Method and standards
Definitions.
Where it is used
- Energy audits.
- Cogeneration net export.
Common mistakes
- Rated motor power used instead of measured.
Assumptions and limits
- Measured loads.
References
- Definitions (sum of drives; kWh/t = kW ÷ t/h)
Questions and answers
Typical figure?
Roughly 12–30 kWh per tonne of steam for solid-fuel boilers; more with ESP and wet scrubbers.
Biggest consumers?
ID fan and feed pumps.
How to cut it?
VFDs on fans and pumps, lower excess air and tighter ducts.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.