Worked example
Example: La Rance-like: 22 km2, 8.5 m range, 33 %, 706 tides, 240 MW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Basin area | 22.000 km² |
| Tidal range | 8.5000 m |
| Overall conversion efficiency | 33.000 % |
| Tides used per year (semidiurnal: about 706) | 706.00 - |
| Seawater density | 1,025.0 kg/m³ |
| Installed capacity | 240.00 MW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Theoretical energy per tide | 2,219.1 MWh |
| Net energy per tide | 732.30 MWh |
| Annual energy | 517.00 GWh |
| Average power | 58.978 MW |
| Capacity factor | 24.574 % |
Open this example in the calculator and change any input.
Formula
\(E_{tide} = \frac{1}{2}\rho gAR^2, \quad E_{yr} = \eta n_tE_{tide}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Basin area | m² |
| \(R\) | Tidal range | m |
| \(\eta\) | Overall conversion efficiency | - |
| \(n_t\) | Tides used per year (semidiurnal: about 706) | - |
| \(\rho\) | Seawater density | kg/m³ |
| \(P_{inst}\) | Installed capacity | W |
| \(E_{tide}\) | Theoretical energy per tide | J |
| \(E_{net}\) | Net energy per tide | J |
| \(E_{yr}\) | Annual energy | J |
| \(\bar P\) | Average power | W |
| \(CF\) | Capacity factor | - |
Method and standards
Potential energy of a tidal basin.
Where it is used
- Screening tidal barrage and lagoon sites.
- Teaching and exam calculations on tidal power.
Common mistakes
- Using the spring range for the whole year.
- Forgetting the conversion efficiency.
Assumptions and limits
- Single basin, mean range; theoretical potential energy.
Questions and answers
Why is the energy proportional to the square of the range?
Both the water volume and its average height above low water grow with the range.
What overall efficiency is realistic?
About 25–35 % of the theoretical energy for single-basin ebb generation; two-way generation and pumping add a little.
What do the defaults represent?
An illustrative case: La Rance-like: 22 km2, 8.5 m range, 33 %, 706 tides, 240 MW. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.