FireCADCalc

Ogee Spillway Discharge with Pier and Abutment Contraction

Discharge over an ogee spillway crest from discharge coefficient, head and effective crest length reduced by pier and abutment contraction, and the unit discharge.

Thermal power plant

Inputs

Examples: Illustrative 60 m crest, 4 piers, 4 m headBarrage 120 m, 10 piers, 6 mSmall dam 15 m, no piers, 1.5 m

Accepted: 1.5 to 2.4
Accepted: 1 to 1,000 m
Accepted: 0 to 50
Accepted: 0 to 0.1
Accepted: 0 to 0.2
Accepted: 0.05 to 30 m

Results

Q = C·L_e·H_e^1.5, L_e = L − 2(NK_p + K_a)H_e. C is about 2.1–2.2 (SI) at the design head for a high ogee with negligible approach velocity, lower at smaller heads and for low weirs or submerged tailwater; take it from the design charts for the spillway's shape and head ratio.

Effective crest length58.880m
Discharge1,012.7m³/s
Discharge per metre of crest17.200m³/(s·m)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 60 m crest, 4 piers, 4 m head. The inputs, in the units selected above:

InputValue
Discharge coefficient (SI)2.1500 -
Net crest length60.000 m
Number of piers4.0000 -
Pier contraction coefficient0.010000 -
Abutment contraction coefficient0.10000 -
Total head on the crest4.0000 m

Applying the formula below gives:

ResultValue
Effective crest length58.880 m
Discharge1,012.7 m³/s
Discharge per metre of crest17.200 m³/(s·m)

Open this example in the calculator and change any input.

Formula

\(Q = CL_eH_e^{3/2}, \quad L_e = L - 2(NK_p + K_a)H_e\)

Variables

Symbol Meaning SI unit
\(C\) Discharge coefficient (SI) -
\(L\) Net crest length m
\(N\) Number of piers -
\(K_p\) Pier contraction coefficient -
\(K_a\) Abutment contraction coefficient -
\(H_e\) Total head on the crest m
\(L_e\) Effective crest length m
\(Q\) Discharge m³/s
\(q\) Discharge per metre of crest m³/(s·m)

Method and standards

Spillway discharge.

Where it is used

  • Small dam and barrage spillway checks.
  • Rating curves for hydro intakes.

Common mistakes

  • Using the coefficient in feet units with metres.
  • Ignoring approach velocity head on low weirs.

Assumptions and limits

  • Free (unsubmerged) flow over a standard crest.

References

  • Ogee crest discharge equation

Questions and answers

Why reduce the crest length for piers?

Flow contracts around piers and abutments, so the effective length carrying flow is shorter than the net clear span.

Why does the coefficient vary with head?

The crest shape is designed for one head; at lower heads the nappe clings and C falls, at higher heads sub-atmospheric pressures raise it.

What do the defaults represent?

An illustrative 60 m net crest with four piers (K_p 0.01), abutments K_a 0.1, C 2.15 and 4 m head.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

US Bureau of Reclamation, Design of Small Dams, 3rd ed. (1987)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.