Worked example
Example: Illustrative 60 m crest, 4 piers, 4 m head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Discharge coefficient (SI) | 2.1500 - |
| Net crest length | 60.000 m |
| Number of piers | 4.0000 - |
| Pier contraction coefficient | 0.010000 - |
| Abutment contraction coefficient | 0.10000 - |
| Total head on the crest | 4.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Effective crest length | 58.880 m |
| Discharge | 1,012.7 m³/s |
| Discharge per metre of crest | 17.200 m³/(s·m) |
Open this example in the calculator and change any input.
Formula
\(Q = CL_eH_e^{3/2}, \quad L_e = L - 2(NK_p + K_a)H_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Discharge coefficient (SI) | - |
| \(L\) | Net crest length | m |
| \(N\) | Number of piers | - |
| \(K_p\) | Pier contraction coefficient | - |
| \(K_a\) | Abutment contraction coefficient | - |
| \(H_e\) | Total head on the crest | m |
| \(L_e\) | Effective crest length | m |
| \(Q\) | Discharge | m³/s |
| \(q\) | Discharge per metre of crest | m³/(s·m) |
Method and standards
Spillway discharge.
Where it is used
- Small dam and barrage spillway checks.
- Rating curves for hydro intakes.
Common mistakes
- Using the coefficient in feet units with metres.
- Ignoring approach velocity head on low weirs.
Assumptions and limits
- Free (unsubmerged) flow over a standard crest.
References
- Ogee crest discharge equation
Questions and answers
Why reduce the crest length for piers?
Flow contracts around piers and abutments, so the effective length carrying flow is shorter than the net clear span.
Why does the coefficient vary with head?
The crest shape is designed for one head; at lower heads the nappe clings and C falls, at higher heads sub-atmospheric pressures raise it.
What do the defaults represent?
An illustrative 60 m net crest with four piers (K_p 0.01), abutments K_a 0.1, C 2.15 and 4 m head.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
US Bureau of Reclamation, Design of Small Dams, 3rd ed. (1987)