Worked example
Example: 20 MW under 15 m, hub 0.35, speed ratio 2.0, flow ratio 0.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shaft power | 20,000 kW |
| Net head | 15.000 m |
| Overall efficiency | 90.000 % |
| Hub to tip diameter ratio | 35.000 % |
| Speed ratio u_tip/√(2gH) | 2.0000 - |
| Flow ratio V_f/√(2gH) | 60.000 % |
| Water density | 1,000.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow | 151.07 m³/s |
| Axial flow velocity | 10.291 m/s |
| Runner tip diameter | 4.6151 m |
| Hub diameter | 1.6153 m |
| Tip speed | 34.304 m/s |
| Speed | 141.96 rpm |
| Specific speed (rpm, kW, m) | 680.10 |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{P}{\rho gH\eta_o}, \quad Q = \frac{\pi}{4}(D^2 - d^2)V_f, \quad V_f = \psi\sqrt{2gH}\)
\(u = \phi\sqrt{2gH} = \frac{\pi DN}{60}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Shaft power | W |
| \(H\) | Net head | m |
| \(\eta_o\) | Overall efficiency | - |
| \(d/D\) | Hub to tip diameter ratio | - |
| \(\phi\) | Speed ratio u_tip/√(2gH) | - |
| \(\psi\) | Flow ratio V_f/√(2gH) | - |
| \(\rho\) | Water density | kg/m³ |
| \(Q\) | Flow | m³/s |
| \(V_f\) | Axial flow velocity | m/s |
| \(D\) | Runner tip diameter | m |
| \(d\) | Hub diameter | m |
| \(u\) | Tip speed | m/s |
| \(N\) | Speed | rad/s |
| \(N_s\) | Specific speed (rpm, kW, m) | - |
Method and standards
Axial-flow turbine continuity and speed relations.
Where it is used
- Preliminary runner sizing for low-head river and canal sites.
- Comparing hub ratios and speeds.
Common mistakes
- Forgetting the hub area in the continuity equation.
- Using the mean blade speed instead of the tip speed in the speed ratio.
Assumptions and limits
- One-dimensional flow; uniform axial velocity.
Questions and answers
Why is the hub ratio important?
The hub blocks part of the flow area; a larger hub houses the blade-pivoting mechanism of a Kaplan but needs a larger runner for the same flow.
How does a Kaplan differ from a propeller turbine?
Its blades pivot with load, keeping efficiency high over a wide flow range; a fixed-blade propeller suits steady flow.
What do the defaults represent?
A 20 MW Kaplan under 15 m at 90 % overall efficiency, hub ratio 0.35, tip speed ratio 2.0 and flow ratio 0.6: about 151 m³/s, a 4.6 m runner (1.6 m hub) turning near 142 rpm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10 (axial-flow reaction turbines)