FireCADCalc

Hydro Turbine Specific Speed, Unit Quantities and Synchronous Speed

Specific speed, unit speed, unit power and unit discharge of a hydraulic turbine, the generator poles for synchronous speed and the usual turbine type.

Thermal power plant

Inputs

Examples: 10 MW per runner under 100 m at 500 rpm, 50 Hz (Francis)Pelton: 25 MW under 600 m at 375 rpm, 50 HzKaplan: 20 MW under 15 m at 125 rpm, 60 Hz

Accepted: 0.001 to 1,000,000 kW
Accepted: 1 to 2,000 m
Accepted: 3.6 to 3,600,000 m³/h
Accepted: 9.5493 to 3,819.7 rpm
Accepted: 10 to 100 Hz

Results

Typical metric specific speeds (rpm, kW, m): Pelton about 8–50 (more with several jets), Francis about 50–350, Kaplan and propeller about 250–850; the head range narrows the choice further.

At this specific speed the usual choice is a Pelton wheel.

Specific speed (metric: rpm, kW, m)19.967
Specific speed in metric horsepower units23.282
Unit speed N/√H15.309
Unit power P/H^1.5 (kW)1.7010
Unit discharge Q/√H0.19188
Generator poles (even, nearest)16.000
Synchronous speed with those poles375.00rpm
Specific speed at the synchronous speed19.967

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 MW per runner under 100 m at 500 rpm, 50 Hz (Francis). The inputs, in the units selected above:

InputValue
Shaft power per runner10,000 kW
Net head100.00 m
Flow per runner41,400 m³/h
Proposed speed500.00 rpm
Grid frequency50.000 Hz

Applying the formula below gives:

ResultValue
Specific speed (metric: rpm, kW, m)158.11
Specific speed in metric horsepower units184.37
Unit speed N/√H50.000
Unit power P/H^1.5 (kW)10.000
Unit discharge Q/√H1.1500
Generator poles (even, nearest)12.000
Synchronous speed with those poles500.00 rpm
Specific speed at the synchronous speed158.11

Open this example in the calculator and change any input.

Formula

\(N_s = \frac{N\sqrt{P}}{H^{5/4}}, \quad N_u = \frac{N}{\sqrt H}, \quad P_u = \frac{P}{H^{3/2}}, \quad Q_u = \frac{Q}{\sqrt H}\)

\(N = \frac{120f}{p}\)

Variables

Symbol Meaning SI unit
\(P\) Shaft power per runner W
\(H\) Net head m
\(Q\) Flow per runner m³/s
\(N\) Proposed speed rad/s
\(f\) Grid frequency 1/s
\(N_s\) Specific speed (metric: rpm, kW, m) -
\(N_{s,hp}\) Specific speed in metric horsepower units -
\(N_u\) Unit speed N/√H -
\(P_u\) Unit power P/H^1.5 (kW) -
\(Q_u\) Unit discharge Q/√H -
\(p\) Generator poles (even, nearest) -
\(N_{syn}\) Synchronous speed with those poles rad/s
\(N_{s,syn}\) Specific speed at the synchronous speed -

Method and standards

Similarity laws of hydraulic turbines.

Where it is used

  • Preliminary turbine selection for a hydro site.
  • Scaling model test results to the prototype.

Common mistakes

  • Mixing kW and metric-horsepower specific speeds.
  • Using gross instead of net head.

Assumptions and limits

  • Geometrically similar machines; one runner (divide power by the number of jets or runners as the convention requires).

Questions and answers

Why does the speed have to be synchronous?

The generator is coupled directly, so N = 120f/p for an even number of poles; the turbine is designed for the nearest such speed.

What units are used?

N in rpm, P in kW and H in m (metric); multiply by 1.166 for metric horsepower, the unit used in many older tables.

What do the defaults represent?

A 10 MW runner under 100 m at about 500 rpm on a 50 Hz grid: N_s about 158 (Francis); 12 poles give 500 rpm exactly.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10, eqs. 10.35, 10.37 and 10.40

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.