Worked example
Example: 10 MW per runner under 100 m at 500 rpm, 50 Hz (Francis). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shaft power per runner | 10,000 kW |
| Net head | 100.00 m |
| Flow per runner | 41,400 m³/h |
| Proposed speed | 500.00 rpm |
| Grid frequency | 50.000 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific speed (metric: rpm, kW, m) | 158.11 |
| Specific speed in metric horsepower units | 184.37 |
| Unit speed N/√H | 50.000 |
| Unit power P/H^1.5 (kW) | 10.000 |
| Unit discharge Q/√H | 1.1500 |
| Generator poles (even, nearest) | 12.000 |
| Synchronous speed with those poles | 500.00 rpm |
| Specific speed at the synchronous speed | 158.11 |
Open this example in the calculator and change any input.
Formula
\(N_s = \frac{N\sqrt{P}}{H^{5/4}}, \quad N_u = \frac{N}{\sqrt H}, \quad P_u = \frac{P}{H^{3/2}}, \quad Q_u = \frac{Q}{\sqrt H}\)
\(N = \frac{120f}{p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Shaft power per runner | W |
| \(H\) | Net head | m |
| \(Q\) | Flow per runner | m³/s |
| \(N\) | Proposed speed | rad/s |
| \(f\) | Grid frequency | 1/s |
| \(N_s\) | Specific speed (metric: rpm, kW, m) | - |
| \(N_{s,hp}\) | Specific speed in metric horsepower units | - |
| \(N_u\) | Unit speed N/√H | - |
| \(P_u\) | Unit power P/H^1.5 (kW) | - |
| \(Q_u\) | Unit discharge Q/√H | - |
| \(p\) | Generator poles (even, nearest) | - |
| \(N_{syn}\) | Synchronous speed with those poles | rad/s |
| \(N_{s,syn}\) | Specific speed at the synchronous speed | - |
Method and standards
Similarity laws of hydraulic turbines.
Where it is used
- Preliminary turbine selection for a hydro site.
- Scaling model test results to the prototype.
Common mistakes
- Mixing kW and metric-horsepower specific speeds.
- Using gross instead of net head.
Assumptions and limits
- Geometrically similar machines; one runner (divide power by the number of jets or runners as the convention requires).
Questions and answers
Why does the speed have to be synchronous?
The generator is coupled directly, so N = 120f/p for an even number of poles; the turbine is designed for the nearest such speed.
What units are used?
N in rpm, P in kW and H in m (metric); multiply by 1.166 for metric horsepower, the unit used in many older tables.
What do the defaults represent?
A 10 MW runner under 100 m at about 500 rpm on a 50 Hz grid: N_s about 158 (Francis); 12 poles give 500 rpm exactly.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10, eqs. 10.35, 10.37 and 10.40