Run-of-River Hydro Energy from a Flow Duration Curve

Annual energy and capacity factor of a run-of-river hydro scheme from a flow duration curve, the design flow, the turbine's minimum flow, head and efficiency.

Thermal power plant

Inputs

Examples: Illustrative stream, 4 m3/s turbine, 40 mLarge turbine 8 m3/sSmall scheme 0.5 m3/s, 120 m head

Accepted: 0 to 36,000,000 m³/h
Accepted: 0 to 36,000,000 m³/h
Accepted: 0 to 36,000,000 m³/h
Accepted: 0 to 36,000,000 m³/h
Accepted: 0 to 36,000,000 m³/h
Accepted: 36 to 36,000,000 m³/h
Accepted: 0 to 90 %
Accepted: 0 to 3,600,000 m³/h
Accepted: 1 to 2,000 m
Accepted: 30 to 100 %

Results

Flow duration curve linear between the given exceedance points (flat beyond 5 % and 95 %); usable flow = min(Q − Q_res, Q_d), zero below the turbine minimum. Efficiency is taken constant; real part-load efficiency curves lower output at low flows. Water density 1,000 kg/m³.

Rated power at design flow470.72kW
Annual energy3,002.4MWh
Capacity factor72.812%
Mean flow used1,310.6m³/h
Time at or above design flow47.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative stream, 4 m3/s turbine, 40 m. The inputs, in the units selected above:

InputValue
Flow exceeded 5 % of the time43,200 m³/h
Flow exceeded 20 % of the time21,600 m³/h
Flow exceeded 50 % of the time10,800 m³/h
Flow exceeded 80 % of the time5,400.0 m³/h
Flow exceeded 95 % of the time2,880.0 m³/h
Design (turbine) flow14,400 m³/h
Minimum turbine flow (fraction of design)25.000 %
Residual (compensation) flow left in the river1,080.0 m³/h
Net head40.000 m
Turbine and generator efficiency85.000 %

Applying the formula below gives:

ResultValue
Rated power at design flow1,333.7 kW
Annual energy7,441.2 MWh
Capacity factor63.691 %
Mean flow used9,171.5 m³/h
Time at or above design flow37.000 %

Open this example in the calculator and change any input.

Formula

\(E = \eta\rho gH_n\cdot 8760\,h\cdot\frac{1}{100}\int_0^{100}\min\left[\max(Q(p) - Q_{res}, 0), Q_d\right]dp\)

Variables

Symbol Meaning SI unit
\(Q_{5}\) Flow exceeded 5 % of the time m³/s
\(Q_{20}\) Flow exceeded 20 % of the time m³/s
\(Q_{50}\) Flow exceeded 50 % of the time m³/s
\(Q_{80}\) Flow exceeded 80 % of the time m³/s
\(Q_{95}\) Flow exceeded 95 % of the time m³/s
\(Q_d\) Design (turbine) flow m³/s
\(f_{min}\) Minimum turbine flow (fraction of design) -
\(Q_{res}\) Residual (compensation) flow left in the river m³/s
\(H_n\) Net head m
\(\eta\) Turbine and generator efficiency -
\(P_r\) Rated power at design flow W
\(E\) Annual energy J
\(CF\) Capacity factor -
\(\bar Q_{used}\) Mean flow used m³/s
\(t_{design}\) Time at or above design flow -

Method and standards

Flow duration energy.

Where it is used

  • Small hydro feasibility.
  • Choosing turbine size.

Common mistakes

  • Using the mean flow without the duration curve.
  • Forgetting the residual flow.

Assumptions and limits

  • Constant efficiency; piecewise-linear flow duration curve.

References

  • Flow-duration method for run-of-river hydro

Questions and answers

How is the design flow chosen?

Often near the flow exceeded 20–40 % of the time; a larger turbine catches more flood water but runs part-loaded or idle more of the year.

Why leave a residual flow?

Regulations require a compensation flow to keep the river's ecology alive; it is never available to the turbine.

What do the defaults represent?

An illustrative stream with 12, 6, 3, 1.5 and 0.8 m³/s exceeded 5, 20, 50, 80 and 95 % of the time, a 4 m³/s turbine down to 25 %, 0.3 m³/s residual flow, 40 m head and 85 % efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011), Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.